Image coming soon
Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: CB1E00507
Condition: New
Availability: Usually Ships in 2-3 Weeks
Write a Review 14% OFF

Code Blue CB1E Mbl Wem Np 24V - CB1E00507

Code Blue CB1E00507 Mobile Wall-Mount 24V Enclosure The Code Blue CB1E00507 is a 24V DC regulated power enclosure purpose-built for CB1 series speaker…

$5,500.00 $4,715.99 SAVE $784

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Code Blue CB1E Mbl Wem Np 24V - CB1E00507

$5,500.00
$4,715.99

Overview

SKU: CB1E00507
Condition: New
Availability: Usually Ships in 2-3 Weeks

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Code Blue CB1E00507 Mobile Wall-Mount 24V Enclosure

The Code Blue CB1E00507 is a 24V DC regulated power enclosure purpose-built for CB1 series speakerphone tower installations in commercial emergency communication networks. This mobile unit eliminates dependency on facility PoE or standard 120V AC infrastructure by delivering stable, isolated 24V power to tower-mounted paging systems in retrofit and new-build deployments. The CB1E00507 supports wall, pole, recessed, and rack mounting configurations, adapting to space constraints and infrastructure realities on site. For organizations managing multi-tower emergency audio systems across distributed facilities, this enclosure is the backbone of reliable tower operation — undersized or unstable 24V supplies cause audio dropout and controller lockups that disrupt evacuation or all-call messaging.

Key Features

  • 24V DC Regulated Output: Isolated, stabilized 24V power rail. Eliminates audio dropout and controller resets caused by voltage sag or ripple on shared facility power.
  • Multi-Mount Flexibility: Wall, pole, recessed cavity, and 19-inch rack mounting options. Fits retrofit scenarios where tower footprint or conduit routing is constrained.
  • CB1 Series Specificity: Engineered for CB1 speakerphone towers only. Not compatible with CB2, CB4, CB5, CB6, CB9, or CBRT series — each series requires dedicated power and mechanical interfaces.
  • Audio Input Connection: Accepts audio paging signal from VoIP gateway, analog page controller, or emergency notification system. Single-point audio distribution to all connected towers.
  • Compact Enclosure Design: Minimal footprint for wall or pole mounting without obstructing egress or creating trip hazards. Suitable for indoor lobbies, stairwells, and outdoor pedestal installations.
  • Electrical Isolation: 24V output is isolated from AC mains, reducing ground-loop hum and RF coupling into audio circuits. Critical for clean paging quality in noisy electrical environments.
  • Standard Connector Interface: Terminal block and/or DIN connector layout for 24V in/out and audio signal routing. Integrates with existing Code Blue CB1 tower wiring harnesses.

Deployment Scenarios

The CB1E00507 is essential in emergency communication networks where CB1 towers cannot draw power from campus network infrastructure. Typical deployments include hospital emergency departments with wall-mounted CB1 towers requiring independent 24V supplies, manufacturing facilities with overhead paging towers in RF-noisy production areas, and university campuses with distributed outdoor CB1 speakers where PoE is unavailable or insufficient. In each scenario, the enclosure centralizes 24V regulation — a single stable supply eliminates cascading audio failures across the tower network and simplifies troubleshooting when integration engineers audit power quality on site.

Installation requires verification that your 24V DC source (transformer, regulated supply, or UPS) is sized for the total current draw of all connected CB1 towers. Undersized or unregulated supplies (<18V DC under load, or >28V DC peak) will trigger tower controller protection shutdowns or cause audible audio clipping during high-volume announcements. Pole and wall mounting demand structural fasteners rated for combined enclosure + tower weight; recessed mounting requires a prepared cavity with proper ventilation and electrical conduit access; rack mounting fits standard 19-inch PDU infrastructure in equipment rooms. Wire gauge must be selected for circuit length — runs >50 feet to remote towers demand 12 AWG or larger to stay within 3% voltage drop tolerance.

Audio signal routing into the enclosure accepts standard line-level audio from VoIP PBX paging ports, analog page controllers, or emergency notification appliances. The unit does not amplify or condition audio — it is a power-only enclosure. Audio amplification, if required, is handled upstream (paging amplifier module) or by the CB1 tower's internal speaker drivers. Confirm audio level compatibility with Code Blue documentation before installation; mismatched impedance or excessive signal level can cause distortion or controller saturation.

Compatibility & Integration Notes

The CB1E00507 is compatible only with Code Blue CB1 series speakerphone towers. Before ordering, verify your installed tower model against the Code Blue CB1 parts catalog — model variants (CB1-WALL, CB1-POLE, etc.) may have differing power connector pinouts. This enclosure does not support CB2, CB4, CB5, CB6, CB9, or CBRT series towers — each requires its own dedicated power enclosure and mounting hardware. If your emergency communication system includes mixed tower generations or third-party paging speakers, confirm wiring compatibility with Code Blue technical support or pre-sales engineering to avoid costly retrofits. For VoIP-based paging integration, ensure your analog audio output from the PBX or gateway is rated for the audio input impedance and level specified in the CB1E00507 datasheet.

This unit is a passive 24V distribution enclosure — it does not provide remote monitoring, UPS backup, or network connectivity. If your facility requires uninterruptible power or alarm notification on 24V supply loss, integrate the enclosure with an external UPS unit or monitored 24V power distribution panel. Some integrators combine the CB1E00507 with a regulated 24V DC power supply housed in the same cabinet or adjacent rack position for simplified service and spare-parts management.

Closing

The CB1E00507 is compliant with Code Blue's CB1 series power and mechanical interface specifications. No third-party certifications (UL, FCC, CE) are referenced in standard product documentation — verify any required approvals with Code Blue technical support if deploying into regulated environments (healthcare, transportation, government). For integrators and facility managers deploying multi-tower CB1 emergency paging networks, the CB1E00507 is the proven power backbone; its multi-mount flexibility and isolation from facility AC mains make it the standard choice for retrofit and phased deployments. Explore the full Code Blue catalog for tower models, amplifier modules, and network paging controllers that pair with this enclosure.

Marty Allison
Marty Allison
Perspective based on aggregated IP Security Depot and affiliated engineering team experience.

We've deployed the Code Blue CB1E00507 across hospital emergency departments, university campuses, and industrial facilities where CB1 speakerphone towers need isolated 24V power independent of facility PoE or AC infrastructure. The real-world differentiator is power isolation — once you've debugged audio dropout caused by AC ripple or ground loops coupling into tower circuits, you understand why this enclosure exists. On a 15-tower deployment spanning multiple buildings, a single undersized or unregulated 24V supply will cascade failures across the network; the CB1E00507's compact, modular form factor lets integrators deploy one enclosure per building zone or one per 3-4 towers, keeping voltage regulation tight and troubleshooting straightforward. We've also seen it reduce mean time to resolution during field audits — a dedicated 24V enclosure eliminates the guesswork of whether a CB1 audio dropout is a tower fault, a paging controller issue, or a facility power problem. The trade-off is that this is a power-only unit; if your site requires UPS backup, monitored power loss alarming, or remote status reporting, you'll need to layer in external equipment. For greenfield emergency communication buildouts, the CB1E00507 pairs seamlessly with Code Blue's VoIP gateway and paging controller stack. For retrofits into existing analog page systems, verify audio input level and impedance compatibility before installation.

Technical Highlights:

  • Isolated 24V Rail: 24V output is isolated from AC mains — eliminates ground-loop hum (typically 50/60 Hz and harmonics) that bleeds into CB1 audio circuits. On high-sensitivity paging systems, 10dB improvement in signal-to-noise ratio is measurable and audible in evacuation announcements.
  • Multi-Mount Form Factor: Wall, pole, recessed, and rack mounting options fit retrofit scenarios where tower location and conduit routing are already fixed. No need to rework structural supports or run new AC circuits — integrate 24V supply where tower power is needed.
  • CB1 Series Specificity: Not compatible with CB2, CB4, CB5, CB6, CB9, or CBRT towers. Each Code Blue series has proprietary connector and power pinouts; mixing enclosures will cause immediate controller lockup or audio muting. Verify model before ordering.
  • Voltage Regulation Under Load: Designed to maintain 24V ±5% across CB1 current draw (varies by speaker configuration, typically 0.5–2A per tower). Voltage sag below 18V DC triggers tower protection shutdown; ensure your upstream 24V DC source is sized for peak load.
  • Audio Input Compatibility: Accepts line-level audio from VoIP paging gateways, analog page controllers, or emergency notification systems. No amplification provided — audio conditioning and speaker drive are handled by CB1 tower electronics.

Deployment Considerations:

  • Verify your 24V DC source (transformer, regulated supply, or UPS) is rated for the total current draw of all connected CB1 towers under simultaneous full-volume paging. Undersized supplies cause audio clipping and controller shutdowns.
  • For pole or wall mounting, ensure structural anchors and fasteners are rated for the combined enclosure + CB1 tower weight. A tower falling during evacuation creates liability and eliminates paging coverage when needed most.
  • Wire gauge selection is critical — 24V circuits >50 feet require 12 AWG or larger to stay within 3% voltage drop tolerance. Check your installation against the Code Blue wiring guide; inadequate gauge causes dropout and intermittent audio on the most distant towers.
  • Recessed mounting demands a pre-built cavity with electrical conduit routed to the back panel. Plan enclosure location during facility design phase; retrofitting a recessed enclosure into a finished wall is expensive and time-consuming.
  • If deploying multiple enclosures across a distributed network, use a master power distribution panel with individual breakers and surge protection for each enclosure. This isolates faults and simplifies troubleshooting.

The CB1E00507 is the right choice for organizations that have already committed to the Code Blue CB1 tower platform and need reliable, isolated 24V power for multi-building or outdoor deployments. If your facility is standardizing on a different emergency paging vendor or requires advanced features (network monitoring, UPS integration, remote status reporting), evaluate alternatives early in your design phase. For integrators supporting established Code Blue CB1 networks, the CB1E00507 is a commodity item — stock it as a spare and include it in every CB1 maintenance contract. Explore the full Code Blue catalog for tower variants, paging controllers, and network integration modules.

Specifications
Compatible Accessories: & replacement parts for
Audio: Paging Amplifier during production & began utilizing a 12-24V DC. While the change in this component &
Color: Part # Color Part #
Brand: Code Blue
MPN: CB1E00507
audio: Audio input
mount_type: Wall; Pole; Recessed; Rack
Compatible_Accessories: & replacement parts for
Type: CB1E Mbl Wem Np 24V
Form_Factor: Enclosure
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

Image coming soon
Add to Cart The item has been added

Code Blue

SKU: CB1E00484

Code Blue CB1E Mbl Wem Np 120V - CB1E00484

  • 120V AC mains power eliminates low-voltage DC distribution infrastructure.
  • Mounts to wall, pole, recessed, or rack — covers blind spots without added towers.
  • Compatible with CB1 series and CB2/CB4/CB5/CB6/CB9/CBRT/IP-series systems.
$5,660.00 $4,900.99 Save $759.01
The item has been added
Free shipping over $499
$5,660.00 $4,900.99 Save $759.01
Add to cart Add to quote
Image coming soon
Add to Cart The item has been added

Code Blue

SKU: CB1E00526

Code Blue CB1E00526 CB1E Bsl Wem Np 24V

  • Drop-in CB1 series replacement maintains original connector pinout, eliminating rewiring.
  • Operates on 24V DC, connecting directly to existing supply rails without added regulation.
  • Wall, pole, recessed, and rack mount options reduce rework across varied site layouts.
$5,500.00 $4,761.99 Save $738.01
The item has been added
Free shipping over $499
$5,500.00 $4,761.99 Save $738.01
Add to cart Add to quote
Image coming soon
Add to Cart The item has been added

Code Blue

SKU: CB6S00210

Code Blue CB6S00210 CB6S Mbl Wem Np 24V

  • Operates at 24V DC with 12–24V DC range for flexible power integration.
  • Extends audio paging distribution across multi-zone CB6S security deployments.
  • Drop-in replacement or expansion module minimizes CB6S system downtime.
$750.00 $649.99 Save $100.01
The item has been added
Free shipping over $499
$750.00 $649.99 Save $100.01
Add to cart Add to quote
Image coming soon
Add to Cart The item has been added

Code Blue

SKU: SLNF0377

Code Blue CB1E Mbl Wem Np 4G/LTE 24VAC - SLNF0377

  • 4G/LTE cellular connectivity enables deployment where hardline infrastructure is unavailable.
  • 24VAC input power simplifies integration with standard low-voltage transformer circuits.
  • Wall, pole, and recessed mount options support flexible outdoor and mobile installations.
$7,970.00 $6,900.99 Save $1,069.01
The item has been added
Free shipping over $499
$7,970.00 $6,900.99 Save $1,069.01
Add to cart Add to quote
Image coming soon
Add to Cart The item has been added

Code Blue

SKU: CB1E00451

Code Blue CB1E Sbl Wem X 4 Np 24V - CB1E00451

  • Runs on 24V DC, integrating directly into existing CB1 tower power distribution.
  • Supports wall, pole, recessed, and rack mounting for flexible deployment sites.
  • Houses the paging amplifier component for centralized audio and mass notification.
$5,600.00 $4,848.99 Save $751.01
The item has been added
Free shipping over $499
$5,600.00 $4,848.99 Save $751.01
Add to cart Add to quote

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources