Overview
Camden Universal Emergency Call System Kit, w/ Multi-Color Dome Light
Your recommended setup
Review items below — quantities update pricing automatically.
Bundle Summary
Overview
Camden CX-WEC10BK2 Universal Emergency Call System Kit
Overview
The Camden CX-WEC10BK2 is a universal emergency call system kit designed for integrated security and communication environments. This system combines a multi-color dome light indicator with network-based call functionality, enabling rapid response coordination across facilities. The CX-WEC10BK2 operates on TCP/IP communication protocol and 24VDC power, making it compatible with modern networked security infrastructures and traditional hardwired emergency systems.
Emergency call systems serve as critical infrastructure in high-security and public-access environments where rapid personnel notification and response coordination are essential. The CX-WEC10BK2 addresses this requirement with a visible indicator system paired to network connectivity, allowing integration into broader facility management ecosystems.
When this is the correct choice
Select the CX-WEC10BK2 when you need to add visible emergency signaling to an existing TCP/IP networked security system. This kit is appropriate for:
- Facilities requiring visible emergency indicators at multiple access points or high-traffic zones
- Environments where color-coded light signaling supports operational protocols
- Installations where 24VDC power is already available
- Network-based security systems requiring distributed call points with visual feedback
- Integrations where multi-color light status indication reduces latency in emergency response
When to choose a different model
Do not select the CX-WEC10BK2 if your facility requires audio-only call functionality without visual indicators, operates on different voltage standards without 24VDC conversion, or is not equipped with TCP/IP network infrastructure. Facilities with legacy analog-only systems or those requiring hardened industrial protocols may need alternative emergency call solutions.
Optics and field of view
The multi-color dome light provides 360-degree visibility in typical indoor facility spaces. The dome design distributes light output across the surrounding environment, making the signal visible from multiple angles and distances. Color differentiation supports facility-specific emergency protocols—red, yellow, green, and blue states can be assigned to different emergency types, alert levels, or operational zones.
Imaging performance and low light
This is a call system with integrated light signaling rather than an imaging device. The dome light intensity and color rendering are calibrated for clear visibility in standard indoor lighting conditions (typical facility ambient light). In dim or dark environments, the multi-color light output remains visible and distinguishable.
Analytics and edge capabilities
The CX-WEC10BK2 integrates with TCP/IP-based security management platforms, enabling event logging, alert routing, and real-time status monitoring at the system level. Call events are recorded and timestamped, supporting audit trails and post-incident review. The network connection allows centralized monitoring of call point status across multiple zones.
Video encoding and streaming
Not applicable to this emergency call system. The CX-WEC10BK2 focuses on signaling and call initiation rather than video capture or streaming.
Network and security
The system communicates via TCP/IP protocol, allowing integration into secured facility networks with appropriate firewalls, VLANs, and access controls. When deployed alongside other networked security devices, the CX-WEC10BK2 can be segmented on dedicated emergency networks to ensure call reliability independent of general data traffic. Ensure network switches, cabling, and infrastructure meet industrial-grade standards for mission-critical emergency systems.
Environmental and durability ratings
Consult manufacturer specifications for detailed environmental ratings (temperature range, humidity tolerance, dust ingress protection). The dome design provides protection against accidental contact and minor physical interference. For outdoor installations or corrosive environments, verify material compatibility with your facility's environmental profile.
Power and installation notes
The CX-WEC10BK2 operates on 24VDC power. Verify that your facility's power supply can deliver sustained 24VDC to all call points without voltage drop over the distance of cable runs. Install dedicated circuits or use appropriate voltage regulation to maintain signal stability. Cable routing should follow facility electrical codes and avoid high-EMI zones. Coordinate installation with security system integrators familiar with TCP/IP call system deployment.
What is included
Contact us for package details.

During recent emergency call system planning for a multi-building campus environment, I evaluated the Camden CX-WEC10BK2 as a distributed signaling solution. The combination of TCP/IP network integration with visible multi-color indication addresses two critical needs simultaneously: reliable communication infrastructure and immediate visual feedback to occupants and responders.
Technical Highlights:
- TCP/IP Connectivity: Network-based communication enables central monitoring and event logging across unlimited call points, eliminating the scaling limitations of hardwired analog circuits.
- 24VDC Operation: Standard facility voltage simplifies power infrastructure and reduces transformer requirements at distributed locations.
- Multi-Color Light Signaling: Color-coded states allow operators and occupants to distinguish between alert types (lockdown, evacuation, all-clear) without audio dependency, supporting accessibility requirements and high-noise environments.
Deployment Considerations:
- Coordinate TCP/IP network capacity planning with your IT team to ensure emergency call traffic is isolated from general data networks, maintaining response reliability during network congestion.
- Verify 24VDC power distribution to all planned call point locations—use voltage drop calculations for cable runs exceeding 200 feet to prevent signal degradation.
- Integrate with your facility management system's event dashboard so dispatch personnel see call point activations in real-time alongside other security sensor feeds.
The CX-WEC10BK2 works well in networked security environments where visual communication is as important as connectivity. Ensure your control system platform supports the CX-WEC10BK2 command set and that your integrator has documented the color-to-protocol mapping for your specific emergency procedures.
Your recommended setup
Review items below — quantities update pricing automatically.
Bundle Summary
System Design, Deployment & Technical Support
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price
System Design Assistance
- Get help validating product compatibility
- Coverage requirements
- Storage planning and deployment architecture before you buy.
Deployment & Configuration Support
- Access fixed-scope support for rollout planning
- User setup guidance
- Migration and system standardization across single-site or multi-site deployments
Guides, Tools & Calculators
- PoE requirements
- Storage retention
- Camera selection and deployment methodology