APC Smart UPS 3000VA LCD RM 2U 120V with 12FT Cord - SMT3000R2X145

APC by Schneider Electric SMT3000R2X145 3000VA 2U Rack Mount UPS 120VOverviewThe APC by Schneider Electric SMT3000R2X145 is a 3000VA, 2U rack-mount un…

$3,150.00 $2,097.99 SAVE $1052
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

APC Smart UPS 3000VA LCD RM 2U 120V with 12FT Cord - SMT3000R2X145

$3,150.00
$2,097.99

Overview

SKU: SMT3000R2X145
UPC: 731304294092
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric SMT3000R2X145 3000VA 2U Rack Mount UPS 120V

Overview

The APC by Schneider Electric SMT3000R2X145 is a 3000VA, 2U rack-mount uninterruptible power supply designed for server rooms, point-of-sale environments, and network closets where clean, conditioned power and short-term runtime during outages are non-negotiable. Drawing on a NEMA L5-30P plug at 120V input and delivering 120V output across eight protected receptacles, this unit fits directly into standard 2U rack space and takes a 12-foot cord to the panel — useful when your PDU or dedicated circuit is on the other side of a rack row. If you're protecting a dense switch stack, a small virtualized server cluster, or a POS lane bank, the SMT3000R2X145 is sized for that exact workload.

Key Features

  • 3000VA Capacity: 3000VA is enough headroom to carry multiple 1U/2U servers, a managed PoE switch, and associated storage through a brief outage or a controlled shutdown sequence — without forcing you to load-shed between devices. It's the right tier for small to mid-density rack environments before you step up to a 5000VA frame.
  • 2U Rack Form Factor: Two rack units is the industry standard for this power class. You get full UPS protection without sacrificing a disproportionate slice of your rack real estate. Pairs cleanly with 1U PDUs above or below.
  • 8 Protected Outlets — Mixed NEMA Configuration: The receptacle layout (six NEMA 5-15R + two NEMA 5-20R) means you can directly connect standard 15A server and networking gear on the 5-15R ports while reserving the two 5-20R ports for higher-draw devices like workstations, high-density switches, or NAS units. No adapter splicing required for mixed-draw environments.
  • NEMA L5-30P Input Plug: The locking L5-30P plug connects to a dedicated 30A twist-lock circuit — not a standard wall outlet. This is deliberate: it eliminates accidental disconnection on a live rack and ensures the UPS draws from a circuit sized for its full load. Verify your panel or PDU has an L5-30 receptacle before ordering.
  • 12-Foot Cord: At 3.66 meters, the input cord reaches a panel or PDU on the opposite side of most standard rack bays without requiring an extension or re-routing the rack. Shorter cords are a frequent install-day problem on high-VA units; 12 feet eliminates that friction.
  • 459 Joule Surge Rating: Surge suppression is built in at 459 joules — meaningful protection against line noise and transient spikes for connected networking and server equipment, though it's not a substitute for upstream surge protection on long building runs.
  • Lead-Acid Battery: Sealed lead-acid chemistry is field-replaceable without tools in most APC Smart-UPS rack frames — a key operational consideration for sites where battery swap needs to happen during business hours without a full shutdown. Confirm battery cartridge compatibility at time of service.
  • LCD Display: The front-panel LCD gives you at-a-glance status on load percentage, estimated runtime, battery condition, and input/output voltage — without requiring software or network access. Useful during initial commissioning and during incidents when your monitoring stack may itself be offline.
  • Front-Mounting Orientation: Rack-mount orientation is front-accessible, meaning the display and controls face outward in a standard rack. No blind installation or rear-panel-only status.

Integration & Compatibility

The SMT3000R2X145 is built for server, networking, and point-of-sale applications. APC Smart-UPS rack units in this class support USB and serial communication ports for UPS management software integration — enabling graceful OS shutdown, runtime monitoring, and event logging through PowerChute or compatible third-party UPS management tools. Verify port availability and software compatibility with your specific OS environment. The unit is compatible with standard 19-inch rack enclosures at 2U height. Input requires a dedicated NEMA L5-30 30A circuit; do not connect to a standard 15A or 20A outlet.

Frequently Asked Questions

Q: What input plug does the SMT3000R2X145 use, and what circuit is required?

A: The SMT3000R2X145 uses a NEMA L5-30P locking input plug and requires a dedicated 30A twist-lock circuit at 120V. It cannot be plugged into a standard 15A or 20A wall outlet.

Q: How many outlets does the SMT3000R2X145 provide, and what types?

A: It provides 8 total protected outlets: six NEMA 5-15R (standard 15A) and two NEMA 5-20R (20A), allowing direct connection of mixed-draw server and networking equipment without adapters.

Q: What is the rack space requirement for the SMT3000R2X145?

A: The SMT3000R2X145 occupies 2U (two rack units) in a standard 19-inch rack enclosure and is front-accessible for display and controls.

Q: What type of battery does the SMT3000R2X145 use?

A: It uses a sealed lead-acid battery. APC Smart-UPS rack units in this class typically support field-replaceable battery cartridges — confirm the compatible replacement cartridge SKU before scheduling a swap.

Q: What equipment is the SMT3000R2X145 recommended for?

A: APC lists this unit for servers, point-of-sale systems, routers, switches, and hubs — specifically in multi-core or virtualized server environments where clean power and orderly shutdown capability are required.

Q: What is the surge rating on the SMT3000R2X145?

A: The SMT3000R2X145 provides 459 joules of surge suppression on all connected outlets, protecting equipment from line transients and voltage spikes.

Jerry Tildsen
Jerry Tildsen

The SMT3000R2X145 is the unit I spec when a site has a dedicated 30A twist-lock circuit and needs 3000VA of true rack UPS protection in 2U — the L5-30P input is the gating factor, and it's also the feature that makes it the right tool for the job. Unlike units that run off a standard 20A circuit and leave you wondering if someone will accidentally unplug the UPS during a maintenance pass, the locking L5-30P means the connection is intentional and secure.

Technical Highlights:

  • 3000VA / 2U: High power density for the rack footprint — carries a multi-server stack or a dense PoE switch environment through an outage without requiring a 3U or 4U chassis.
  • Mixed Outlet Bank (6x 5-15R + 2x 5-20R): The two 5-20R ports are the detail most buyers overlook until install day. Having native 20A receptacles means your higher-draw NAS, workstation, or high-wattage switch connects directly — no cheater adapters creating a code or warranty issue.
  • 459J Surge + LCD: The front LCD lets you verify load percentage and battery health at the rack door without remoting in — critical during the first 48 hours after installation when you're dialing in load balance across outlets.

Deployment Considerations:

  • Confirm the panel or in-row PDU has an available NEMA L5-30 30A receptacle before the unit ships to site — this is the single most common install blocker on this model class, and a field-fabricated adapter is not a compliant solution.
  • The 12-foot input cord is generous, but if your rack is center-of-room and your panel is on the wall, measure the actual run before assuming it reaches — 12 feet goes fast when you account for cord management and bend radius.

For a virtualized server closet or a security operations rack running NVR, managed PoE switches, and access control servers off a dedicated 30A circuit, the SMT3000R2X145 is sized correctly and installs clean — this is not a unit to shoehorn into a standard outlet environment.

Specifications
Store: Hours
Nema Rating: 6
Type: Multi-Core or Virtualized Server Areas
Connectivity: NEMA L5-30P
Mounting Type: Rack
Use With: Servers, Point-of-Sale, Routers, Switches, Hubs
Color: Black
Battery Type: Lead-Acid battery
Connector Configurations: 6 NEMA5-15R, 2 NEMA5-20R
Cord Length: 12 ft (3.66 m)
Input Voltage: 120 V
Nema Configuration: 5-15R
Mounting Location: Front
No. Of Outlets: 8
Orientation: lower
Output Voltage: 120 V
Plug Configuration: NEMA L5-30
Rack Units: 2
Rated Joules: 459 Joules
Receptacle Configuration: (2) NEMA 5-20/(6) NEMA 5-15
Va Rating: 3000VA
Color Family: Black
Dimensions: 3.39 in.
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources