Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: AR3308B2
UPC: 731304753377
Condition: New
Write a Review 33% OFF

APC Netshelter SX Server Rack GEN 2 52U 2436H X 600W X 1200D MM with Sides - AR3308B2

APC by Schneider Electric AR3308B2 52U NetShelter SX Gen 2 Server Rack EnclosureOverviewThe APC by Schneider Electric AR3308B2 is a 52U, second-genera…

$6,155.00 $4,097.99 SAVE $2057
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

APC Netshelter SX Server Rack GEN 2 52U 2436H X 600W X 1200D MM with Sides - AR3308B2

$6,155.00
$4,097.99

Overview

SKU: AR3308B2
UPC: 731304753377
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric AR3308B2 52U NetShelter SX Gen 2 Server Rack Enclosure

Overview

The APC by Schneider Electric AR3308B2 is a 52U, second-generation NetShelter SX server rack enclosure finished in white, measuring 600 mm wide by 1200 mm deep — a configuration suited to enterprise server rooms, data center rows, and IT closets where a full-height, standard-depth cabinet is required. Side panels are included, providing a closed cabinet form factor out of the box. If you are sourcing server rack enclosures for a structured equipment room buildout, this is the APC NetShelter SX variant to evaluate for full-height, side-panel-enclosed deployments.

Key Features

  • 52U Rack Capacity: 52U of usable vertical space is one of the largest standard configurations available in the NetShelter SX line — appropriate for dense compute stacks, patch panels, and power distribution units in a single cabinet without requiring a second enclosure for overflow.
  • 600 mm Wide × 1200 mm Deep Footprint: The 600 mm width is a standard data center column dimension, compatible with hot/cold aisle containment systems and raised-floor tile grids designed around that spacing. The 1200 mm depth accommodates deep 1U/2U servers without forced cable bend-radius compression at the rear.
  • Integrated Cable Management: Built-in cable management provisions reduce post-installation remediation work — structured cabling from servers, patch panels, and PDUs can be routed and dressed during rack population rather than retrofitted later.
  • Side Panels Included: The enclosed cabinet configuration (versus open-frame) provides a physical separation boundary between adjacent aisles or non-rack equipment zones — relevant for environments where a degree of physical access control per-cabinet is required without a full cage build-out.
  • White Finish: The white colorway distinguishes this unit from the standard black NetShelter SX variants. Useful in environments where cabinet color codes zones or where white finish is a facilities requirement (clean rooms, certain healthcare IT rooms).
  • RoHS Compliant: RoHS compliance confirms restricted substances (lead, mercury, cadmium, etc.) are within EU directive limits — a procurement requirement for many government, healthcare, and international enterprise projects.

Integration & Compatibility

The AR3308B2 follows standard 19-inch EIA-310 rack rail spacing, accepting any EIA-compliant 1U–52U equipment. It is compatible with the broader APC by Schneider Electric ecosystem including NetShelter-series blanking panels, PDUs, cable management accessories, and side-panel extensions. For high-density deployments, pair with a rack PDU and structured cable management accessories to maximize usable space within the 52U column. When planning power delivery to equipment housed in this enclosure, review your rack PDU selection guide to match outlet count and amperage to your specific load.

Frequently Asked Questions

Q: What is the rack unit capacity of the AR3308B2?

A: The AR3308B2 provides 52U of usable rack space.

Q: Does the AR3308B2 come with side panels?

A: Yes, side panels are included with this unit, providing a fully enclosed cabinet configuration.

Q: What are the external dimensions of the AR3308B2?

A: The enclosure is 600 mm wide and 1200 mm deep. The height corresponds to a 52U cabinet (approximately 2436 mm as indicated in the product name).

Q: Is the AR3308B2 RoHS compliant?

A: Yes, the AR3308B2 carries RoHS compliance certification.

Q: What color is the AR3308B2?

A: This variant is finished in white, differentiating it from the standard black NetShelter SX models.

Q: Is the AR3308B2 compatible with standard 19-inch rack equipment?

A: Yes, the NetShelter SX uses standard EIA-310 19-inch rail spacing, compatible with any compliant rack-mount equipment.

Specifications
Rack capacity: 52U
Product colour: White
Cable management: Yes
Width: 800 mm
Depth: 1200 mm
Weight: 201.5 kg
Compliance certificates: RoHS
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources