Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: E-1600-20A-EWPCE
UPC: 615687222425
Condition: New
Write a Review 52% OFF

Viking E-1600-20A-EWPCE 2-Button ADA Emergency Phone IP66 EWP

Viking Electronics E-1600-20A-EWPCE ADA Emergency Phone with EWP and CE MarkOverviewThe Viking Electronics E-1600-20A-EWPCE is an ADA-compliant, two-b…

$1,006.00 $485.99 SAVE $520
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Viking E-1600-20A-EWPCE 2-Button ADA Emergency Phone IP66 EWP

$1,006.00
$485.99

Overview

SKU: E-1600-20A-EWPCE
UPC: 615687222425
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Viking Electronics E-1600-20A-EWPCE ADA Emergency Phone with EWP and CE Mark

Overview

The Viking Electronics E-1600-20A-EWPCE is an ADA-compliant, two-button handsfree emergency phone built for demanding environments — parking structures, elevator lobbies, transit platforms, and any location where reliable emergency communication must survive weather extremes. Telephone-line powered with no separate supply needed, it mounts flush (with the included rough-in box) or surface-mounts with an optional VE-5x5 enclosure. The Enhanced Weather Protection (EWP) variant carries an IP66 rating and a CE Mark, making it a direct candidate for outdoor covered locations or industrial settings where humidity routinely hits 100%.

Where standard Viking 1600A Series phones top out at 5% to 95% non-condensing humidity, the E-1600-20A-EWPCE pushes to full 100% humidity tolerance — the right call for car washes, pool facilities, or coastal outdoor enclosures. Explore the full Viking Electronics emergency phone lineup to compare series options side by side.

Key Features

  • Telephone Line Powered: Draws power directly from the POTS line — no local AC circuit, no PoE switch, no UPS to provision. This simplifies rough-in significantly in concrete stairwells or elevator machine rooms where pulling a separate power circuit is expensive and code-intensive.
  • Up to 5 Emergency + 2 Central Station Numbers: Program up to five sequential emergency destination numbers and two dedicated central station numbers. If the first number doesn't answer within the configured timeout, the unit rolls to the next — critical for 24/7 monitored facilities where a single point of failure in the call chain is unacceptable.
  • Three Non-Emergency Info Button Numbers: The E-1600-20A-EWPCE supports up to three non-emergency numbers on the information button — useful for directing callers to a front desk, maintenance line, or tenant directory without consuming emergency slots.
  • 16-Second Voice Memory: Onboard voice announcer plays a pre-recorded 16-second message on pickup — eliminating the need for a live attendant to confirm location. In a multi-building campus, recording the building name, floor, and nearest landmark into that 16 seconds gives dispatch immediately actionable data without asking the caller.
  • IP66 Weather Protection (EWP): IP66 means sustained high-pressure water jets and total dust ingress protection — the unit will handle driving rain, power washing, or salt-spray environments. If you need submersion (fountains, flood-prone pits), you'd need IP67 or IP68; IP66 is the right spec for 95% of outdoor above-grade installations.
  • ADA Compliant: Meets ADA requirements out of the box — no add-on hardware or extra modification needed to satisfy accessibility code in commercial occupancies. Confirm local jurisdiction requirements before commissioning, but the hardware compliance is built in.
  • Operating Range -30°F to 170°F (-34°C to 77°C): That low end covers unheated parking garages in northern climates without a heater kit. The 170°F ceiling handles direct-sun metal enclosures in southern exposures — a range most competing units don't publish at this width.
  • 304 Stainless Steel Construction: The E-1600-SSA Series faceplate is 304 stainless with a red fine-texture powder paint finish — corrosion-resistant in coastal or high-humidity environments and resistant to the surface damage that defeats painted steel units over time.
  • Dual Mounting Options: Ships with a rough-in box for flush mounting into a standard wall opening. Surface mount using the optional VE-5x5 enclosure — useful for retrofit installs where cutting into a finished wall isn't practical. Having both paths in one SKU keeps stocking simple.
  • CE Mark: The CE designation confirms the unit meets European conformity requirements for electromagnetic compatibility and safety — relevant if you're deploying in EU-regulated facilities or for a global campus with standardized procurement.

Integration and Compatibility

The E-1600-20A-EWPCE connects to any standard analog POTS telephone line — no VoIP adapter, no SIP configuration, no IP network required. This is a deliberate design choice: analog lines remain the most reliable infrastructure in emergencies (no router to reboot, no network dependency). For facilities transitioning away from POTS, confirm analog line availability or provision an ATA before commissioning.

The unit pairs naturally with a monitored access control and emergency notification infrastructure. Central station monitoring numbers can be programmed alongside building security desk numbers, so a single button press reaches the right escalation chain. For broader deployment planning, the emergency phone category covers companion Viking models including IP-based variants for all-digital plants.

Mounting dimensions for the stainless steel faceplate (E-1600-SSA Series) are 5.75

Specifications
Product Name: E-1600-20A-EWPCE
Power: Telephone line powered
Operating Temperature: -30° F to 170° F (-34° C to 77° C)
Humidity Standard Products: 5% to 95% non-condensing
Humidity EWP Products: Up to 100%
Dimensions E-1600A Series: 5.25” x 4.0” x 2.0” (133 mm x 102 mm x 51 mm)
Shipping Weight E-1600A Series: 2.5 lbs (1.13 kg)
Material E-1600A Series: Steel
Finish E-1600A Series: Red powder paint
Dimensions E-1600-SSA Series: 5.75” x 3.08” x 1.05” (146 mm x 78 mm x 27 mm)
Shipping Weight E-1600-SSA Series: 2.5 lbs (1.3 kg)
Material E-1600-SSA Series: 304 stainless steel
Finish E-1600-SSA Series: Red fine texture powder paint
Dimensions E-1600-02A: 13” x 10.5” x 2” (330 mm x 267 mm x 51 mm)
Shipping Weight E-1600-02A: 7 lbs (3.18 kg)
Material E-1600-02A: Brushed stainless steel
Dimensions E-1600-03B: 7.22” x 5.36” x 1.55” (183 mm x 149 mm x 39 mm)
Shipping Weight E-1600-03B: 3 lbs (1.36 kg)
Material E-1600-03B: Marine grade 316 stainless steel
IP Rating: IP66 (with EWP)
Compliance: ADA Compliant
Dialing Capacity: Up to 5 emergency numbers, 2 central station numbers
Info Button Capacity: Up to 3 non-emergency numbers (E-1600-20A/E-1600-52A)
Voice Memory: 16 seconds
Mounting: Flush mount or Surface mount
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources