Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: E-1600A-RT-EWP
Condition: New
Write a Review 52% OFF

Viking E-1600A-RT-EWP ADA Emergency Phone IP66 Ramtel Flush Mount

Viking Electronics E-1600A-RT-EWP ADA Emergency Phone with Enhanced Weather ProtectionOverviewThe Viking Electronics E-1600A-RT-EWP is a marine-grade …

$1,170.00 $564.99 SAVE $605
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Viking E-1600A-RT-EWP ADA Emergency Phone IP66 Ramtel Flush Mount

$1,170.00
$564.99

Overview

SKU: E-1600A-RT-EWP
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Viking Electronics E-1600A-RT-EWP ADA Emergency Phone with Enhanced Weather Protection

Overview

The Viking Electronics E-1600A-RT-EWP is a marine-grade 316 stainless steel emergency phone engineered for flush mounting in Ramtel PLC columns, towers, wall mounts, and 926/906 back boxes. Built to ADA compliance requirements and rated for IP66 weather protection, this unit covers harsh outdoor environments — parking structures, transit platforms, campus blue-light stations, and industrial facilities where a phone needs to work at -30°F and keep functioning at 170°F without degradation. The E-1600A-RT-EWP (often searched as E 1600A RT EWP) runs entirely on telephone line power, which eliminates local power wiring and simplifies installation in remote or column-mounted locations.

Key Features

  • Marine Grade 316 Stainless Steel Faceplate: 316 alloy provides superior corrosion resistance compared to standard 304 stainless — relevant at coastal sites, pool facilities, or anywhere salt air or chemical washdown is a regular occurrence. The brushed finish also reduces glare and hides surface wear over time.
  • IP66 Enhanced Weather Protection: EWP models meet IP66 standards via foam rubber gaskets and sealed connections, meaning sustained high-pressure water jets won't penetrate the housing. This is the right spec for uncovered outdoor mounting — not just splash-resistant, but genuinely weatherproof.
  • Telephone Line Powered — No Local Power Required: The unit draws from the telephone loop directly (minimum 24V DC talk battery, 20mA loop current). No AC transformer, no conduit run for power — one cable handles both power and voice, which cuts installation cost significantly in column or tower installations where pulling a second circuit is expensive.
  • Operating Range -30°F to 170°F (-34°C to 77°C): This temperature window handles unheated parking decks in northern climates and sun-baked enclosures in southern ones. Most competitive emergency phones top out at 140°F — the 170°F ceiling matters in metal enclosures on south-facing walls in summer.
  • Up to 5 Programmable Emergency Numbers + 2 Central Station Numbers: Seven total programmable destinations give dispatchers flexibility to route calls by priority or time-of-day, without requiring a separate controller for multi-destination dialing.
  • 16-Second Voice Memory: Pre-recorded location announcements play automatically on pickup, giving dispatch an immediate location ID before the caller speaks — reduces response time in large campuses or multi-structure deployments where callers may not know their exact location.
  • Auxiliary Relay Output: Dry contact rated 0.5A @ 125VAC / 1A @ 30VDC, plus a wet output at +12VDC. Wire this to a strobe, door release, or CCTV trigger — the relay lets the phone become part of a broader emergency response sequence without an external controller.
  • Flush Mount for Ramtel Infrastructure: Designed specifically to mount in Ramtel PLC columns, towers, 926 and 906 boxes. If your site already runs Ramtel infrastructure, this is the correct phone — it drops in without fabrication or adapter plates.

Integration and Compatibility

The E-1600A-RT-EWP integrates with standard POTS telephone infrastructure and is compatible with Ramtel PLC columns, towers, and 926/906 back boxes. The BLK-4 Control Module (powered separately at 120V AC or 12V DC at 500mA) supports expanded control functions. The auxiliary relay output supports integration with strobe lights, access control systems, or CCTV triggers for coordinated emergency response. The E-1600A-RT-EWP operates at standard telephone loop levels — verify your DEMARC or VoIP ATA delivers at least 24V DC talk battery and 20mA loop current before commissioning.

Frequently Asked Questions

Q: What is the IP rating of the E-1600A-RT-EWP?

A: The E-1600A-RT-EWP carries IP66 protection via foam rubber gaskets and sealed connections, protecting against sustained high-pressure water jets and dust ingress.

Q: Does the E-1600A-RT-EWP require a separate power supply?

A: No. The phone is telephone line powered — it draws from the loop directly, requiring a minimum 24V DC talk battery voltage and 20mA loop current. No local AC power is needed for the phone itself. The optional BLK-4 Control Module requires 120V AC or 12V DC at 500mA if used.

Q: What temperature range does the E-1600A-RT-EWP support?

A: It operates from -30°F to 170°F (-34°C to 77°C), making it suitable for both extreme cold outdoor installations and high-heat enclosed metal column environments.

Q: How many emergency numbers can be programmed?

A: Up to 5 emergency numbers and 2 central station numbers, for 7 total programmable destinations.

Q: What back boxes and mounting structures is the E-1600A-RT-EWP designed for?

A: It flush mounts to Ramtel PLC columns, towers, wall mounts, and Ramtel 926 and 906 back boxes.

Q: Can the E-1600A-RT-EWP trigger external devices like strobes or door releases?

A: Yes. The unit includes an auxiliary relay rated at 0.5A @ 125VAC / 1A @ 30VDC (dry contact) and a +12VDC wet output, suitable for driving strobes, CCTV triggers, or access control inputs.

Karl Wilson
Karl Wilson

The E-1600A-RT-EWP stands out specifically because of its 316 marine-grade stainless construction combined with IP66 sealing — that combination is not universal in the emergency phone category, and it matters on coastal campuses, natatorium facilities, or any site where 304 stainless would pit and gaskets would dry-rot inside two winters. The -30°F to 170°F operating range also gives it a meaningful edge over units that tap out at 140°F in enclosed column installations.

Technical Highlights:

  • Telephone Line Power (24V DC / 20mA min): Single-cable install in Ramtel columns — no AC conduit run needed, which is the primary cost driver in tower and column deployments where trenching or conduit extension is expensive.
  • 16-Second Voice Memory: Automatic location announcement on pickup. On a 40-building campus where callers frequently don't know their exact position, this alone materially reduces dispatch response time.
  • Auxiliary Relay (0.5A @ 125VAC / 1A @ 30VDC dry; +12VDC wet): Enough to drive a strobe directly or feed an access control panel input — integrators can build a coordinated response trigger without adding a separate relay module.

Deployment Considerations:

  • Verify your telephone infrastructure — VoIP ATAs and some hosted PBX systems do not reliably deliver 24V DC talk battery at 20mA loop current. Test at the DEMARC before commissioning; an underpowered loop produces intermittent audio or failed calls under cold-weather load.
  • The E-1600A-RT-EWP is dimensioned for Ramtel infrastructure specifically (8.281" x 11.938" x 2.0"). If your site uses a different column or enclosure manufacturer, confirm cutout dimensions before ordering — this is not a universal-fit faceplate.

Best deployment fit: university and transit authority blue-light programs running existing Ramtel column infrastructure in northern climates where freeze-thaw cycling and coastal salt air are regular design constraints. The IP66 rating and 316 alloy make it the right specification choice where standard stainless emergency phones have failed corrosion review.

Specifications
Product Name: E-1600A-RT-EWP
Material: Marine grade 316 stainless steel
Faceplate Material: Marine grade 316 stainless steel
Faceplate Finish: Brushed
Mounting Type: Flush Mount
Dimensions E-1600A-RT-EWP: 8.281” x 11.938” x 2.0”
Dimensions E-1600A-RTM-EWP: 6.500” x 8.500” x 2.0”
Shipping Weight E-1600A-RT-EWP: 3.8 lbs
Shipping Weight E-1600A-RTM-EWP: 2.8 lbs
Phone Power: Telephone line powered
Minimum Talk Battery Voltage: 24V DC
Minimum Loop Current: 20mA
BLK-4 Control Module Power: 120V AC/12V DC 500mA
Operating Temperature: -30° F to 170° F
Operating Temperature Celsius: -34° C to 77° C
Humidity: Up to 100%
Programmable Numbers: Up to 5 emergency, 2 central station
Voice Memory: 16 seconds
Auxiliary Relay Rating: 0.5A @ 125VAC / 1A @ 30VDC (Dry)
Auxiliary Relay Output: +12VDC (Wet)
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources