Door Hardware & I/O
Sub categories
Showing Results for Door Hardware & I/O
-
HES
SKU: DC-82BP
HES DC-82BP Dress Cover Model 82 Brass Polished
Polished brass dress cover for HES Model 82 strike systems
- Polished brass finish with standard door frame mounting for indoor commercial installations
- Purpose-built for HES Model 82 access control hardware compatibility
- Protects strike equipment while maintaining finished appearance and accessibility
$184.00 $99.99 Save $84.01 -
HES
SKU: DC-82CL
HES DC-82CL Dress Cover for Model 82
Clear anodized dress cover for HES Model 82 housings
- Direct fit for Model 82 with no modifications to base housing
- Clear anodized aluminum maintains optical clarity for camera operation
- Rated for indoor and outdoor deployments in security installations
$77.00 $41.99 Save $35.01 -
HES
SKU: DC-82SP
HES DC-82SP Model 82 Dress Cover Stainless Polish
Polished stainless steel dress cover for HES Model 82 security gear
- Stainless steel with polished finish resists corrosion indoors and outdoors
- Wall-mounted or surface-mounted configuration for flexible installation
- Protects equipment from dust, debris, and weather exposure
$175.00 $94.99 Save $80.01 -
HES
SKU: DC-MM15BK
HES DC-MM15BK Dress Cover for Model MM15
Black protective cover for HES MM15 mounting hardware
- Shields MM15 components from dust, debris, and weather exposure
- Wall and ceiling mount compatible with standard MM15 configurations
- Black finish maintains discrete, professional appearance in any setting
$61.00 $32.99 Save $28.01 -
HES
SKU: DC-MM15BP
HES DC-MM15BP Dress Cover Model MM15 Polished Brass
Polished brass dress cover for HES Model MM15 electric strikes
- Conceals mounting hardware while maintaining full access control function
- Polished brass finish suits commercial, institutional, and residential doors
- Direct fit for HES Model MM15 strike installations; US-made construction
$152.00 $81.99 Save $70.01 -
HES
SKU: DC-MM15BS
HES DC-MM15BS Dress Cover Model MM15 Satin Brass
Satin brass dress cover for HES Model MM15 locks, no modification
- Conceals electromagnetic lock mechanism while maintaining full maintenance access
- Satin brass finish resists corrosion in commercial environments
- Drop-in installation requires zero alterations to base lock assembly
$165.00 $88.99 Save $76.01 -
HES
SKU: DCP-12X3
HES DCP-12X3 Dress Cover Plate 12x3 inch
12x3 dress cover plate for HES M380+ electric strikes
- Covers larger electric strike cutouts at 12x3 inches for a clean frame finish.
- Compatible with HES M380 and similar larger electric strike models.
- Durable construction handles high-traffic commercial and institutional environments.
$49.00 $48.99 Save $0.01 -
HES
SKU: DDC-32BK
HES DDC-32BK Dress Cover Model 32 Double
Dual-camera dress cover for wall and ceiling mount dome/turret installations
- Protects two cameras from dust, debris, and moisture in commercial settings
- Compatible with dome and turret form factors for flexible deployment options
- Wall and ceiling mounting supports synchronized dual-camera security layouts
$182.00 $97.99 Save $84.01 -
HES
SKU: DDC-32CL
HES DDC-32CL Dress Cover Model 32 Double
Protective cover for Model 32 Double housings with optical clarity
- Environmental shielding maintains full sensor performance and field access
- Compatible with wall and ceiling mount configurations for flexible placement
- Designed for commercial, industrial, retail, and hospitality installations
$182.00 $97.99 Save $84.01 -
HES
SKU: DDC-62BK
HES DDC-62BK Dress Cover Model 62 Double
Cable concealment cover for HES Model 62 double camera setups
- Hides wiring, cables, and mounting hardware for clean professional appearance
- Designed for indoor controlled environments without restricting maintenance access
- Protects infrastructure from dust and debris in customer-facing installations
$182.00 $97.99 Save $84.01 -
HES
SKU: DDC-62CL
HES DDC-62CL Model 62 Double Dress Cover
Protective dress cover for HES Model 62 dual-camera systems
- Shields cameras in indoor and outdoor environments with integrated housing
- Maintains optical clarity and sensor access with standard mounting brackets
- Purpose-built for HES Model 62 double camera configurations, no custom parts
$182.00 $97.99 Save $84.01 -
HES
SKU: DE-1
HES DE-1 Delayed Egress Station
Wall-mounted delayed egress station for institutional access control
- Integrates with HES and third-party access control systems via standard electrical connections
- Wall-mount design sized for indoor institutional and commercial security deployments
- Manages controlled exit scenarios in educational, healthcare, and corporate facilities
$370.00 $204.99 Save $165.01 -
HES
SKU: DE-1RED
HES DE-1RED Delayed Egress Station 2G Stainless Steel
Adjustable 2–45 second delayed egress station with key override
- 2G stainless steel construction rated for high-contact healthcare and education environments
- Red push button with key reset mechanism for authorized personnel emergency bypass
- Compatible with HES power supplies and door control systems, 35VDC input
$426.00 $234.99 Save $191.01 -
HES
SKU: DK-12
HES DK-12 Digital Keypad System Illuminated
Illuminated PIN keypad for standalone or integrated access control
- Backlit display for reliable operation in low-light and after-hours access
- 24VDC powered keypad with Wiegand output for direct panel integration
- Supports up to 92 doors in networked HES access control deployments
$261.00 $260.99 Save $0.01 -
HES
SKU: DK-26PBK
HES DK-26PBK Digital Keypad Narrow Stile
Narrow stile digital keypad for HES electric strikes in space-constrained doors
- Compact form factor fits aluminum and steel frames where wide stile units won't fit
- Supports up to 59 users with standard access control wiring integration
- Indoor-rated for commercial and institutional buildings, retrofit or new construction
$309.00 $308.99 Save $0.01 -
HES
SKU: DK-26PSS
HES DK-26PSS Digital Keypad Narrow Stainless Steel
Narrow stainless steel keypad for tight spaces and corrosive environments
- Stainless steel construction resists salt spray, rust, and oxidation
- Compact narrow profile fits retrofit installations where standard keypads won't
- Operates on 12VDC or 24VDC for compatibility with existing access control systems
$288.00 $287.99 Save $0.01
Door Hardware & I/O
Door hardware and I/O components connect physical doors to your access control system. From electric strikes and magnetic locks to exit devices and relay modules, proper hardware selection ensures safe, compliant, and reliable operation.
Plan Your Deployment
- Fail-safe vs fail-secure lock configuration
- Door type (wood, metal, glass, storefront)
- Request-to-exit (REX) device requirements
- Power supply and voltage compatibility
- Local life-safety and fire code compliance
Door Hardware & I/O — Engineering-Grade Door Hardware for Commercial Deployments
This category covers 532 working models of door hardware & i/o sourced manufacturer-direct or through channel-direct US distribution. Build the rest of your system around the architectural choices below — compatibility, environmental rating, and lifecycle decisions made here propagate through every downstream component you specify.
What to Look For
Fail-safe versus fail-secure determines what happens during power loss. Fail-safe locks unlock on power loss (used on egress doors where life safety dominates); fail-secure locks remain locked (used on storage, server rooms, and exterior doors where security dominates). Code typically mandates fail-safe on stairwell and egress doors. Confirm with the AHJ before specifying — misapplied lock mode is a common code violation.
Strike, mortise, magnetic lock, and electrified panic hardware each have distinct installation, current draw, and code implications. Electric strikes work with most mechanical locksets and are easiest to retrofit. Magnetic locks (maglocks) provide high holding force on glass and wood doors but require dedicated REX and panic-bar interfaces for egress compliance. Verify the door's existing prep before choosing.
Power draw and inrush current dictate power supply sizing. A 5-door system with 1A peak per lock can exceed an undersized 12VDC supply at simultaneous lock-down events. Account for accessories — REX motion sensors, door-position switches, electrified levers — when sizing the supply and the battery backup required for code compliance.
Tamper switches, door-position monitoring, and request-to-exit sensors generate the audit trail your security team needs. Mechanical contact switches are cheaper; magnetic reed switches resist tampering better. Pair each door with a position switch and a REX sensor at minimum — without door-position monitoring, you can't distinguish 'authorized entry' from 'door held open after authorized entry,' which is a common compliance gap.
Key Specs in This Category
| Spec | Available Options |
|---|---|
| Resolution | 8MP, 2MP |
| IP Rating | IP66, IP67 |
| Connectivity | Wired |
| Power | AC/DC, Battery |
| Type | Accessory, Controller, Cable, Switch, Power Supply, Access Card, Contact, Lock/Strike |
| Night Vision | Yes |
Top Brands in This Category
Frequently Asked Questions
Fail-safe or fail-secure for stairwell doors?
Fail-safe is mandatory on most stairwell doors and other code-designated egress paths — the lock must release on fire alarm or power loss to allow evacuation. Fail-secure on those doors is a code violation. Confirm the local fire code and AHJ requirements; commercial buildings in the U.S. follow NFPA 101 and the International Building Code, both of which detail egress lock behavior in detail.
What current draw should I plan for electrified locks?
Typical 12VDC electric strikes draw 200-500 mA continuous, with inrush spikes of 1-2A at engagement. Magnetic locks rated for 1,200 lbs holding force draw around 500 mA continuous at 24VDC. Power supplies need to handle simultaneous lock-down current — emergency lockdown events activate all locks at once. Size the supply with at least 25% headroom and confirm battery backup runtime requirements.
Do I need a request-to-exit (REX) sensor?
Most code-compliant electrified door installations require a REX sensor to shunt the alarm during authorized egress. Without REX, every egress event registers as a forced-door alarm. PIR motion sensors are the common choice and integrate with the door controller's REX input. Mechanical push-bar REX is also acceptable for hardware that includes that switch natively.
Can I use one lock for both card and mechanical key entry?
Yes — most electrified strikes and locks allow mechanical key override on the same door. Maintaining a master key for emergency mechanical access is required by code in many jurisdictions and recommended in all. Document the master key holders carefully; an uncontrolled master key program undermines the electronic audit trail.
What's the lifespan of a magnetic lock?
Quality maglocks (Securitron M62, HES, von Duprin) typically last 15-20 years with no mechanical wear. Failure points are the connector, the armature plate-to-lock alignment, and contamination of the magnetic face. Plan for armature replacement at year 10 as a hedge against alignment drift. Strike-type locks with mechanical parts last 5-10 years before strike-plate wear becomes a reliability issue.
Need help choosing? Talk to a Senior Specialist — direct line 877-277-7147 or request a quote.