Altronix 24V@10A/2-ACM8CB/BC750 - MAXFIT7FD
Compact power distribution module designed to efficiently manage and distribute 24VDC power to multiple surveillance devices
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Altronix MAXFIT77FD is a compact, multi-output DC power distribution module rated for 2–24VDC input at up to 10A total output — purpose-built for integrators who need to cleanly distribute power from a single supply across multiple access control readers, locks, or surveillance devices without running individual power runs back to a central panel. At 8.00 x 4.50 x 1.25 inches and under a pound, it fits inside almost any backbox or enclosure where space is at a premium.
Altronix has built its reputation on field-serviceable, installation-friendly power products, and the MAXFIT77FD follows that pattern — eight individually fused or managed output positions, each rated at 2.5A, feeding from a shared 10A bus. If you've ever had a single shorted device on a daisy-chain knock out an entire access control run, the per-channel architecture here is the answer. For a deeper look at the broader Altronix power solutions catalog, the full line covers everything from small backbox supplies to rack-mount multi-channel systems.
The MAXFIT77FD is input-agnostic within the 2–24VDC range, making it compatible with the broad range of Altronix power supplies that output 12VDC or 24VDC — including the MAXFIT and NetWay series. It is designed to pair with access control panels, power supply units, and low-voltage surveillance equipment operating in that voltage window. Always verify that the sum of your per-channel loads stays under the 10A aggregate bus limit and that individual device draws don't exceed 2.5A per output. When planning deployments with multiple modules, route each MAXFIT77FD from a dedicated supply circuit to maintain isolation between door groups — a best practice for both fault containment and code compliance on larger access systems. Integrators pairing this module with IP surveillance cameras should confirm camera power input compatibility, as most PoE cameras draw from Ethernet rather than a discrete DC supply.
Q: What input voltage range does the MAXFIT77FD accept?
A: The MAXFIT77FD accepts 2–24VDC input, making it compatible with standard 12VDC and 24VDC low-voltage power supplies commonly used in access control and surveillance installations.
Q: How many output channels does the MAXFIT77FD provide, and what is the per-channel current rating?
A: It provides 8 output channels, each rated at 2.5A maximum. The total aggregate output across all channels is 10A — keep the sum of all simultaneous loads under that threshold when planning your installation.
Q: Can the MAXFIT77FD be used with electromagnetic door locks?
A: Yes. Standard electromagnetic locks draw approximately 500–600mA at 12VDC or 24VDC, which is well within the 2.5A per-channel rating. Each channel has enough headroom to drive a mag lock with margin, or a lock plus a card reader on the same output if total draw stays under 2.5A.
Q: What are the physical dimensions and weight of the MAXFIT77FD?
A: The unit measures 8.00 x 4.50 x 1.25 inches and weighs 0.95 lbs, making it suitable for installation inside standard access control enclosures or backboxes without requiring additional structural support.
Q: Does the MAXFIT77FD provide per-channel fault isolation?
A: The 8-channel architecture is designed so that each output is independently managed. A fault condition on one output channel does not automatically affect the remaining seven — a key advantage over daisy-chain wiring in life-safety and access control applications where continuous operation of other doors is required.

The MAXFIT77FD's 2.5A-per-channel rating is the number I look at first when evaluating a distribution module for access control work. At 2.5A per output across 8 channels with a 10A aggregate bus, this module sits in the sweet spot for mid-size deployments where you need to drive four to eight doors from a single power source without building a custom wiring harness. It's a well-matched fit for the typical eight-door access controller scenario where your upstream supply is already in the 12–24VDC range.
Technical Highlights:
Deployment Considerations:
This module is well-suited for eight-door commercial access control deployments — hotel corridors, office floor buildouts, or warehouse entry zones — where a single regulated supply needs to fan out cleanly to individual door hardware without single-point-of-failure wiring topology.
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Altronix products? Shop the full Altronix catalog →
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price