Middle Atlantic
SKU: JMS-12X6
Overview
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Overview
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Middle Atlantic J-12X6 ships six 1-ft (0.3 m) power jumpers designed for in-rack, short-run connections between rack power distribution units and the equipment mounted directly above or below them. At 12 inches of usable cord length, these jumpers eliminate the excess slack that standard 3- or 6-foot cords create inside a rack — coiled cable is dead airflow blockage and a thermal management problem in dense deployments. If you're commissioning a rack where PDU-to-device distance is measured in rack units rather than feet, the J-12X6 is the right call. Browse the full Middle Atlantic power and rack accessories line for complementary components.
The J-12X6 jumpers are intended for use within Middle Atlantic rack systems, pairing with Middle Atlantic PDUs and rack-mounted equipment requiring short power runs. The 1-ft length is specifically suited to devices installed in adjacent rack units — any device more than a few rack units away from its PDU connection point will need a longer jumper from the same family. Verify PDU outlet orientation and device inlet position before selecting jumper length; in deep or mid-depth rack configurations, 1 ft may not bridge the physical distance even within the same rack section.
Q: How many jumpers are included in the J-12X6 package?
A: The J-12X6 includes 6 jumpers per package.
Q: What is the cord length on the J-12X6 jumpers?
A: Each jumper is 1 ft (0.3 m) in length, designed for short in-rack runs between a PDU and adjacent rack-mounted equipment.
Q: What is the specified depth for the J-12X6?
A: The J-12X6 has a specified depth of 12 in (30.5 cm), consistent with standard Middle Atlantic rack system dimensions.
Q: Are the J-12X6 jumpers suitable for devices mounted several rack units away from the PDU?
A: No — the 1-ft cord is optimized for devices in immediately adjacent rack units. For greater distances within the same rack, a longer jumper from the Middle Atlantic line is the correct choice.
Q: Can I use the J-12X6 jumpers with non-Middle Atlantic PDUs?
A: The J-12X6 is designed for Middle Atlantic rack systems. Compatibility with third-party PDUs depends on connector type and outlet configuration — verify against your specific PDU before ordering.

The detail that matters most with the J-12X6 is the 1-ft (0.3 m) cord length — it sounds trivial until you're staring at a rack where every PDU outlet has a 6-ft jumper coiled three times and zip-tied to itself because nobody ordered the right length. These jumpers exist to solve that specific problem at the rack-build stage, not as an afterthought.
Technical Highlights:
Deployment Considerations:
The J-12X6 is the right pick for integrators building out Middle Atlantic rack systems where PDU-adjacent equipment needs clean, zero-slack power connections — security equipment racks, AV head-end closets, and network equipment enclosures where cable management is part of the deliverable, not an afterthought.