Heat Detectors

Sidebar
Selecting a sort option will reload the product list.

Showing Results for Heat Detectors

  • System Sensor 5151 Electronic Low-Profile Plug-In Heat Detector
    Add to Cart The item has been added

    System Sensor

    SKU: 5151

    System Sensor 5151 Electronic Low-Profile Plug-In Heat Detector

    Low-profile 35VDC heat detector for discrete ceiling/wall mounting

    • Operates at 35VDC for direct integration into conventional fire alarm loops.
    • Low-profile form factor supports discrete ceiling or wall mounting in tight spaces.
    • Thermal detection avoids false alarms in kitchens, loading docks, and mechanical rooms.
    $70.88 $47.99 Save $22.89
    The item has been added
    Free shipping over $499
    $70.88 $47.99 Save $22.89
    Add to cart Add to quote
  • System Sensor 5601P 135F Fixed/Rate-of-Rise Mechanical Heat Detector

    System Sensor

    SKU: 5601P

    System Sensor 5601P 135F Fixed/Rate-of-Rise Mechanical Heat Detector

    Dual-mode 135°F mechanical heat detector for two/four-wire fire loops

    • Dual fixed-temperature (135°F) and rate-of-rise detection reduces nuisance alarms.
    • Runs on 35VDC across two-wire or four-wire fire alarm circuits for flexible integration.
    • Electronics-free mechanical design eliminates firmware dependencies and processor latency.
    $30.45 $21.99 Save $8.46
    The item has been added
    Free shipping over $499
    $30.45 $21.99 Save $8.46
    Add to quote
  • System Sensor 5602 194F Fixed/Rate-of-Rise Mechanical Heat Detector

    System Sensor

    SKU: 5602

    System Sensor 5602 194F Fixed/Rate-of-Rise Mechanical Heat Detector

    Two-wire mechanical heat detector for conventional fire alarm circuits

    • Dual fixed/rate-of-rise detection responds to both steady heat and rapid temperature spikes.
    • Two-wire conventional circuit at 35VDC connects directly to existing FACP without added modules.
    • Mechanical thermal element operates without electronic polling, reducing points of failure.
    $30.98 $21.99 Save $8.99
    The item has been added
    Free shipping over $499
    $30.98 $21.99 Save $8.99
    Add to quote
  • Image coming soon

    System Sensor

    SKU: 5603

    System Sensor 5603 135F Fixed Temperature Mechanical Heat Detector

    135°F fixed heat detector with TCP/IP for networked fire systems

    • Triggers at exactly 135°F for reliable heat detection in dusty or steam-filled spaces.
    • Mechanical sensing requires no electronics, eliminating drift and reducing false alarms.
    • Runs on 35VDC conventional fire alarm loops for straightforward panel integration.
    $26.00 $18.99 Save $7.01
    The item has been added
    Free shipping over $499
    $26.00 $18.99 Save $7.01
    Add to quote
  • System Sensor 5604 194F Fixed Temperature Mechanical Heat Detector (view 3)

    System Sensor

    SKU: 5604

    System Sensor 5604 194F Fixed Temperature Mechanical Heat Detector

    Fixed temperature heat detector for conventional 2-wire fire alarm systems

    • Operates on 35VDC conventional 2-wire loops—no addressable module or converter needed.
    • Box form factor supports ceiling or wall mounting in warehouses and mechanical rooms.
    • Mechanical thermal element requires zero calibration or configuration post-installation.
    $30.98 $21.99 Save $8.99
    The item has been added
    Free shipping over $499
    $30.98 $21.99 Save $8.99
    Add to quote
  • System Sensor 5621 135F Dual-Circuit Fixed/Rate-of-Rise Heat Detector
    Add to Cart The item has been added

    System Sensor

    SKU: 5621

    System Sensor 5621 135F Dual-Circuit Fixed/Rate-of-Rise Heat Detector

    135°F dual-circuit heat detector for conventional and addressable systems

    • Dual-circuit design supports both conventional and addressable panels without relay adapters.
    • 135°F fixed-temp plus rate-of-rise detection reduces nuisance alarms in mixed-use spaces.
    • Operates at 35VDC, compatible with standard conventional fire alarm control panels.
    $56.70 $36.99 Save $19.71
    The item has been added
    Free shipping over $499
    $56.70 $36.99 Save $19.71
    Add to cart Add to quote
  • System Sensor 5622 194F Dual-Circuit Fixed/Rate-of-Rise Heat Detector
    Add to Cart The item has been added

    System Sensor

    SKU: 5622

    System Sensor 5622 194F Dual-Circuit Fixed/Rate-of-Rise Heat Detector

    Dual-circuit heat detector with fixed and rate-of-rise sensing for fire alarm systems

    • Dual fixed-temp and rate-of-rise sensing catches both slow smoldering and fast fires.
    • Operates at 35VDC for direct integration with conventional fire alarm control panels.
    • Ceiling-mount installation follows NFPA 72 spacing standards for commercial deployments.
    $57.23 $35.99 Save $21.24
    The item has been added
    Free shipping over $499
    $57.23 $35.99 Save $21.24
    Add to cart Add to quote
  • System Sensor 5623 135F Dual-Circuit Fixed Temperature Heat Detector
    Add to Cart The item has been added

    System Sensor

    SKU: 5623

    System Sensor 5623 135F Dual-Circuit Fixed Temperature Heat Detector

    135°F fixed-temperature heat detector with dual-circuit conventional and addressable wiring

    • Fixed 135°F thermal setpoint eliminates false alarms in dusty or vapor-heavy spaces.
    • Dual-circuit design supports both two-wire conventional and addressable loops on one SKU.
    • Rated for 35VDC operation; confirm panel voltage and loop config before deployment.
    $57.23 $36.99 Save $20.24
    The item has been added
    Free shipping over $499
    $57.23 $36.99 Save $20.24
    Add to cart Add to quote
  • System Sensor 5624 194F Dual-Circuit Fixed Temperature Heat Detector
    Add to Cart The item has been added

    System Sensor

    SKU: 5624

    System Sensor 5624 194F Dual-Circuit Fixed Temperature Heat Detector

    Dual-circuit fixed temperature heat detector with TCP/IP networking

    • Fixed 194°F activation threshold eliminates sensitivity tuning in high-heat zones.
    • Operates at 35VDC from the FACP—no external power supply or special config needed.
    • Dual-circuit design supports conventional loop wiring for alarm and supervisory states.
    $57.23 $35.99 Save $21.24
    The item has been added
    Free shipping over $499
    $57.23 $35.99 Save $21.24
    Add to cart Add to quote
Heat Detectors

Heat Detectors

Fixed-temperature and rate-of-rise heat detectors for areas where smoke detectors are impractical. Mechanical rooms, kitchens, parking garages, and dusty environments benefit from heat-based detection that avoids nuisance alarms from normal airborne particulates.

Plan Your Deployment

  • Select fixed-temperature rating based on ambient ceiling temperature plus offset margin
  • Evaluate rate-of-rise feature for areas with stable ambient conditions
  • Confirm spacing per NFPA 72 for ceiling height, slope, and obstructions
  • Specify addressable or conventional base to match panel SLC or zone wiring
  • Plan placement in mechanical rooms, garages, and commercial kitchens per code

Heat Detectors — Engineering-Grade Fire Detection for Commercial Deployments

This category covers 0 working models of heat detectors sourced manufacturer-direct or through channel-direct US distribution. Build the rest of your system around the architectural choices below — compatibility, environmental rating, and lifecycle decisions made here propagate through every downstream component you specify.

What to Look For

Addressable versus conventional architecture is the first decision. Conventional systems group detectors into zones; addressable systems identify the exact device that triggered. For buildings above 10,000 sq ft or with more than 20 detectors, addressable saves substantial diagnostic time and meets most modern code requirements. Conventional panels remain economical for small commercial buildings and retrofits where new wiring isn't feasible.

UL 864 listing is non-negotiable for the panel; UL 268 for smoke detectors, UL 521 for heat detectors. The AHJ will reject anything else. Beyond UL, look for FM Approval and CSFM (California) listings — many jurisdictions accept only those. Confirm panel-to-detector compatibility within the manufacturer's listed combinations; mixing brands across UL listings voids the panel's certification.

Notification appliance circuit (NAC) capacity, voltage drop, and battery backup sizing drive panel sizing more than detector count does. ADA-compliant strobes draw 75-175 mA each — a 50-strobe building exceeds many small NAC ratings. Calculate total NAC load with voltage-drop budget for the longest run, and size standby battery for 24 hours plus 5 minutes alarm per NFPA 72.

Central station communication, networked panel federation, and graphical workstations matter most in multi-building campuses. Single-building panels typically dial a central station via cellular and IP; multi-building campuses run proprietary peer-to-peer networks (Notifier NFN, Siemens FN-2127, Edwards SIGA) with master annunciation. Plan the integration topology before ordering panels — head-end choice affects which compatible peripherals you can deploy.

Frequently Asked Questions

Do I need an addressable or conventional fire alarm panel?

Addressable panels identify the specific detector in alarm; conventional panels identify only the zone. NFPA 72 and most local codes require addressable for buildings above certain occupancy or square-footage thresholds, but the practical break-even is around 20-30 detectors. Above that count, addressable saves diagnostic and maintenance time. Below it, conventional is often the budget-friendly choice.

What's the difference between photoelectric and ionization smoke detectors?

Photoelectric detectors respond fastest to smoldering fires (cigarettes, electrical wiring); ionization detectors respond fastest to flaming fires (paper, kitchen). Modern dual-sensor detectors include both technologies and meet UL 268 7th edition requirements. Most jurisdictions now require dual-sensor or photoelectric for new commercial installations. Ionization-only is being phased out due to nuisance-alarm performance in cooking and shower-steam scenarios.

How often must fire alarm systems be inspected?

NFPA 72 requires annual inspection and testing of the entire system, semiannual battery testing, and monthly visual inspection of the panel. Local AHJ requirements often mandate documentation and a service contract with a licensed contractor. The owner-of-record bears legal responsibility for inspections — missing an annual inspection exposes the owner to fines and insurance claim denial.

Do I need a duct smoke detector?

Yes if the HVAC system exceeds 2,000 CFM (commercial threshold) — code requires duct smoke detectors that shut down the HVAC to prevent smoke distribution during a fire. Confirm CFM rating against local code thresholds; many jurisdictions require duct detection on smaller systems serving multiple-occupancy buildings. Duct detectors must report to the building's fire alarm panel.

What battery backup is required for fire panels?

NFPA 72 requires 24 hours of standby operation plus 5 minutes in full alarm. Calculate panel current draw under both conditions, then specify a battery with adequate Ah capacity. Lead-acid batteries lose capacity in cold environments — derate by 20% for unconditioned spaces. Replace batteries every 4-5 years even if they test good; failure rates climb steeply after year 5.

Need help choosing? Talk to a Senior Specialist — direct line 877-277-7147 or request a quote.