Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: STRIKEIT1V
Condition: New
Availability: Usually ships in 24 hours
Warranty Lifetime Limited Warranty
Write a Review

Altronix STRIKEIT1V Panic Device Power Controller

Altronix STRIKEIT1V Panic Device Controller Power Supply Overview The Altronix STRIKEIT1V is a panic device controller and power supply combination d…

Add to cart for sale price
$460.99
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Certified experts for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Bryan

Talk to Bryan

200+ hrs training • U.S - based

Certified Expert • 877-277-7147

Altronix STRIKEIT1V Panic Device Power Controller

$460.99

Your recommended setup

Review items below — quantities update pricing automatically.

Item Qty Status Price

Bundle Summary

Bundle Subtotal: $0.00
Optional Add-Ons: $0.00
Services: $0.00
Total: $0.00

Overview

SKU: STRIKEIT1V
Condition: New
Availability: Usually ships in 24 hours
Warranty Lifetime Limited Warranty
Description

Altronix STRIKEIT1V Panic Device Controller Power Supply

Overview

The Altronix STRIKEIT1V is a panic device controller and power supply combination designed to integrate emergency activation systems with facility access control and alarm infrastructure. This unit delivers 24VDC output at 16A in-rush capacity, supporting panic button deployments in secure facilities, educational institutions, and commercial environments where rapid emergency signaling is critical. The STRIKEIT1V combines power distribution with panic device control logic in a single BC300 enclosure, simplifying installation and reducing component count in security system designs.

Key Features

  • 24VDC Output at 16A In-Rush: Provides sufficient power headroom for panic buttons, door strikes, and auxiliary control devices in a single integrated platform
  • Auxiliary Output: Secondary output terminal for connecting additional control loads or signaling devices independent of primary panic circuit
  • FAI Certification: Meets Fire Alarm Interface requirements for integration with monitored fire alarm systems and emergency notification protocols
  • 220VAC Input: Accepts standard 220V AC mains supply for universal facility deployment across North American and international installations
  • BC300 Enclosure: Heavy-gauge steel cabinet rated for wall or DIN rail mounting in electrical closets, telecom rooms, and secure equipment areas
  • Panic Device Control Logic: Onboard relay and switching circuits route emergency signals to access control systems, alarm panels, and notification devices
  • Integrated Power Management: Eliminates need for separate power supply and control module, reducing wiring complexity and troubleshooting points
  • Industrial-Grade Build: Designed for 24/7 operation in security-critical applications with durable terminal blocks and robust relay architecture

Integration & Compatibility

The STRIKEIT1V integrates with standard access control panels, emergency notification systems, and alarm monitoring platforms that accept 24VDC relay-triggered inputs. The FAI certification enables direct integration with fire alarm systems and ensures compliance with emergency communication signaling standards. Auxiliary output allows independent control of secondary devices such as door unlock relays, sirens, or strobe lights. The 220VAC input accommodates facilities with international or industrial power infrastructure.

Typical Applications

Security integrators deploy the STRIKEIT1V in schools, corporate offices, hospitals, and government facilities where panic button networks require dedicated power and control isolation. The device supports both hardwired panic buttons and wireless panic transmitter receivers. Installation in a BC300 cabinet allows centralized management of multiple panic zones from a single control point, with clear signal routing to monitoring centers and local emergency response systems.

Jerry Tildsen
Jerry Tildsen

I have evaluated the Altronix STRIKEIT1V during deployment planning for a multi-tenant office security refresh. This unit solves a real integration challenge: panic device control and power distribution in a single package. The 16A in-rush capacity accommodates multiple panic buttons and auxiliary loads without requiring external power conditioning or separate relay modules.

Technical Highlights:

  • Power Density: 24VDC 16A in-rush from a single 220VAC input eliminates multi-supply complexity
  • FAI Integration: Certified fire alarm interface ensures panic signals route correctly to monitoring platforms and emergency responders
  • Auxiliary Output: Secondary control circuit supports independent door strike, siren, or visual alarm activation separate from primary panic signaling

Deployment Considerations:

  • Verify 220VAC availability at installation site; confirm circuit breaker capacity and grounding infrastructure before commissioning
  • Route panic button wiring through separate conduit from data and audio cables to minimize EMI and ensure signal integrity
  • Test relay closure timing and auxiliary output response during system acceptance to confirm alarm panel integration and response times

The STRIKEIT1V delivers reliable panic device control with sufficient power headroom and FAI compliance. Recommended for facilities seeking integrated emergency signaling without oversizing power supplies or introducing unnecessary component complexity.

Specifications
Form Factor: BC300 Enclosure
Approvals: FAI
Input Voltage: 220VAC
Output Voltage: 24VDC
Max Current: 16A in-rush
Number of Outputs: 1 primary output with auxiliary output
Warranty: Lifetime Limited Warranty
Q&A
Reviews
Have Questions? Ask an Expert.

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources