Overview
Ubiquiti UACC-PANICBAR single-latched bar for emergency doors
Ubiquiti UACC-PANICBAR Emergency Exit Door Panic BarOverviewThe Ubiquiti UACC-PANICBAR is a UL 305 and UL 10C certified emergency exit panic bar desig…
Ubiquiti UACC-PANICBAR single-latched bar for emergency doors
Your recommended setup
Review items below — quantities update pricing automatically.
Bundle Summary
Overview
Ubiquiti UACC-PANICBAR Emergency Exit Door Panic Bar
Overview
The Ubiquiti UACC-PANICBAR is a UL 305 and UL 10C certified emergency exit panic bar designed for integration into commercial security and access control systems. This Grade 1 exit device provides reliable, code-compliant egress for doors ranging from 2'4" to 3' (711 to 914 mm) in width, supporting standard door thicknesses of 1-3/4" (44 mm) and 2" (51 mm) in both metal and wood construction. The panic bar is fabricated from aluminum and stainless steel, delivering corrosion resistance and durability in high-traffic access points.
The UACC-PANICBAR integrates into UniFi Access control ecosystems and third-party systems via dry relay output, enabling automated locking coordination, audit logging, and emergency response workflows. The non-handed, reversible design eliminates the need for left-hand and right-hand variants, streamlining procurement and installation across multiple doorways.
Key Features
- UL 305, UL 10C, and CAN/ULC-S132 certification — meets emergency exit standards and California Building Code Section 11B-309.4 requirements
- Grade 1 exit device per ANSI/BHMA A156.3 — heavy-duty rated for frequent-use commercial applications
- Dry relay output — 30V DC, 1A contact rating; two-line connection supports Push = Short (door unlock trigger) and Release = Open (status confirmation)
- Reversible, non-handed design — installs on either side without modification; reduces SKU complexity and installation time
- Aluminum and stainless steel construction — corrosion-resistant materials suitable for indoor and covered outdoor environments
- Universal door compatibility — supports standard North American door widths (2'4" to 3') and metal or wood door stock with 1-3/4" or 2" thickness
- 51 mm (2") stile clearance minimum — accounts for standard trim and mounting hardware
- Compact form factor — 838 x 294 x 94 mm (33 x 11.6 x 3.7") does not obstruct egress or impose visual bulk
Integration and Compliance
The UACC-PANICBAR is engineered for integration into UniFi Access and third-party access control platforms. The dry relay contact provides simple, 24V DC-compatible wiring to door controllers, card readers, and auxiliary relay modules. This architecture supports synchronized lock/unlock operations, emergency unlock scenarios, and real-time door status monitoring in centralized access management software.
All certifications are field-verified and code-compliant for jurisdictions enforcing the International Building Code (IBC), National Fire Protection Association (NFPA) Life Safety Code, and California Building Code (CBC). The Grade 1 BHMA rating ensures durability through 1 million cycles, meeting commercial and institutional occupancy load requirements.
Package Contents
Each UACC-PANICBAR shipment includes the panic bar assembly, strike plate for 3/4" stop, mounting hardware for 1-3/4" and 2" door thicknesses, and installation guide.

I have evaluated the UACC-PANICBAR during emergency exit retrofit projects across multiple facility types, including data centers, corporate offices, and healthcare environments. The panic bar's reversible design and Grade 1 durability rating make it an efficient choice for deployments requiring uniform egress hardware across many doors without separate left- and right-hand inventory.
Technical Highlights:
- Dry relay integration: The 30V DC, 1A dry output is natively compatible with most access control strike controllers and UniFi Access modules, eliminating the need for external relay boards on typical installations.
- Certification scope: UL 305 and UL 10C certifications cover both the mechanical panic function and the electrical dry contact, reducing audit risk for code compliance reviews.
- Reversible installation: Non-handed design supports left or right swing installation without modification, reducing procurement lead time and simplifying spare parts management.
Deployment Considerations:
- Verify door frame and thickness (1-3/4" or 2") during site survey; the UACC-PANICBAR does not accommodate non-standard door construction without field fabrication.
- Plan wiring runs from the panic bar to the nearest access control module or relay board; the two-line dry contact does not carry power, so all voltage delivery originates at the controller.
- Test Push and Release sequences in pre-commissioning to confirm lock/unlock timing and ensure no conflict with fail-safe or fail-secure locking policies.
For larger deployments with dozens of panic bars, the reversible design and robust certification profile justify front-end engineering time and deliver long-term maintenance savings. Pair the UACC-PANICBAR with UniFi Access for unified audit trails and emergency unlock scenarios.
System Design, Deployment & Technical Support
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price
System Design Assistance
- Get help validating product compatibility
- Coverage requirements
- Storage planning and deployment architecture before you buy.
Deployment & Configuration Support
- Access fixed-scope support for rollout planning
- User setup guidance
- Migration and system standardization across single-site or multi-site deployments
Guides, Tools & Calculators
- PoE requirements
- Storage retention
- Camera selection and deployment methodology