Ubiquiti UA-G2-SK-PRO G2 Starter Kit Professional
Overview
The Ubiquiti UA-G2-SK-PRO is a complete access control solution designed to deliver entry and exit management for a single door installation. This professional-grade starter kit ships with all core components required to deploy unified access control in small to mid-scale environments. The UA-G2-SK-PRO combines a UniFi Access Door Hub with dual G2 Professional readers and pocket key fob credentials, enabling organizations to implement immediate physical security without requiring additional hardware purchases for basic single-door deployments.
Key Features
- Complete Single-Door Solution: Provides full entry and exit control capability with integrated hub and dual professional readers
- UniFi Access Door Hub: Central management appliance for access policy enforcement and credential administration
- Access Reader G2 Professional (Quantity 2): Dual readers for independent entrance and exit door control, supporting distinct credential validation workflows
- UniFi Access Pocket Key Fob: Physical credential included for immediate operability without requiring external fob procurement
- Professional-Grade Reader Design: G2 Professional reader form factor rated for commercial and institutional deployments
- Unified Management Platform: Integration with UniFi ecosystem for centralized policy deployment and audit logging
Package Contents
The UA-G2-SK-PRO kit includes:
- 1x UniFi Access Door Hub
- 1x Access Reader G2 Professional (entrance/primary reader)
- 1x Access Reader G2 Professional (exit/secondary reader)
- 1x UniFi Access pocket key fob credential
Integration & Compatibility
The UA-G2-SK-PRO operates as part of the UniFi ecosystem, enabling integration with UniFi Cloud gateways and UISP platforms for organizations requiring multi-site credential management and centralized audit trails. The kit supports credential-based access control workflows typical of office buildings, laboratories, data centers, and secure facilities requiring dual-reader configurations for directional flow control.
Deployment Considerations
This starter kit is configured for organizations deploying access control to a single physical door with defined entry and exit reader locations. The inclusion of two Access Reader G2 Professional units enables independent credential validation at both ingress and egress points, supporting workflows where entry credentials differ from exit permissions. Additional readers, magnetic locks, and complementary Ubiquiti access accessories (sold separately) are available to expand deployments to multiple doors or to integrate fail-safe locking mechanisms.
The UA-G2-SK-PRO represents a complete entry point for organizations transitioning from manual or legacy access systems to unified, cloud-integrated access control infrastructure. Professional installers and IT managers should evaluate the kit against facility-specific requirements regarding reader placement, credential types, and integration scope prior to deployment.

I evaluated the Ubiquiti UA-G2-SK-PRO during a small-scale access control refresh for a 20-person research facility. The kit's completeness—shipping with both hub and dual readers—eliminates the common problem of partial kit procurement and subsequent sourcing delays. The inclusion of the pocket key fob means installations can test credential workflows immediately without external fob ordering cycles.
Technical Highlights:
- Dual-Reader Configuration: Separate entrance and exit readers eliminate cross-traffic credential confusion and enable directional access policies native to the system design.
- UniFi Cloud Integration: The Door Hub integrates with UniFi Cloud gateways for multi-site credential synchronization and centralized audit logging, critical for organizations managing access across multiple facilities.
Deployment Considerations:
- Confirm power and network availability at both reader locations before deployment; readers are networked appliances requiring wired connectivity to the hub.
- Plan credential types early in deployment—the included fob is functional but most environments will require card-based or biometric credential expansion beyond the starter kit scope.
The UA-G2-SK-PRO suits organizations that need access control deployed quickly without managing component sourcing separately. It is not a replacement for larger multi-door installations; for those, plan for multiple kits or evaluate gate and elevator starter kits based on facility topology.
System Design, Deployment & Technical Support
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price
System Design Assistance
- Get help validating product compatibility
- Coverage requirements
- Storage planning and deployment architecture before you buy.
Deployment & Configuration Support
- Access fixed-scope support for rollout planning
- User setup guidance
- Migration and system standardization across single-site or multi-site deployments