Overview
Altronix MAXFIT77FE 24VDC 20A Dual-Channel Power Supply
Altronix MAXFIT77FE Dual Power Supply Expandable Power SystemOverviewThe Altronix MAXFIT77FE is a dual-channel expandable power supply designed for mi…
Altronix MAXFIT77FE 24VDC 20A Dual-Channel Power Supply
Your recommended setup
Review items below — quantities update pricing automatically.
Bundle Summary
Overview
Altronix MAXFIT77FE Dual Power Supply Expandable Power System
Overview
The Altronix MAXFIT77FE is a dual-channel expandable power supply designed for mid-to-large scale security and access control installations. This system delivers redundant 24VDC power at 10 amperes per channel, providing architectural flexibility for equipment expansion without redesign. The MAXFIT77FE integrates into the BC750 enclosure, a proven form factor for professional installations where space efficiency and thermal management are critical. Built for integrators who require reliable, scalable power distribution across camera arrays, control processors, and networked access devices.
Key Features
- Dual 24VDC Output: Two independent 24VDC @ 10A channels enable load balancing and equipment segmentation across separate power rails
- Expandable Architecture: System designed to grow with installation scope; additional modules can be integrated without platform replacement
- BC750 Enclosure Integration: Compact, DIN-rail compatible form factor optimized for secure mounting in electrical cabinets and technical closets
- Redundant Power Path: Dual supply channels provide fault tolerance—loss of one channel does not compromise the secondary rail
- Professional-Grade Construction: Industrial-rated components rated for continuous duty cycles in 24/7 security deployments
- Thermal Management: Integrated cooling design maintains stable operation across ambient temperature ranges typical in equipment rooms
Specification Details
Each output channel of the MAXFIT77FE delivers a continuous 24VDC @ 10A, totaling 20 amperes system capacity when both rails are utilized. This capacity supports typical loads including IP cameras (0.5–3A per unit), card readers (0.3–1A), electronic locks (2–4A), and control modules. The redundant channel topology allows integrators to isolate critical loads—for example, access control on Channel 1, surveillance on Channel 2—ensuring that a single point of failure does not cascade across the entire installation.
The BC750 enclosure provides a proven mechanical platform. Its compact footprint suits restricted cabinet space while maintaining adequate thermal clearance for passive cooling. DIN-rail mounting is standard, enabling rapid integration into existing electrical infrastructure.
Integration and Deployment Considerations
The MAXFIT77FE is widely adopted in mid-range commercial security systems, particularly multi-building campuses, retail chains, and industrial facilities where distributed power architecture reduces single-point-of-failure risk. The dual-channel design integrates cleanly with legacy Altronix supervision and monitoring modules, though the MAXFIT77FE itself operates as a standalone supply unit.
Installers should verify total load against the 10A per-channel specification before deployment. Real-world implementations typically allocate 2–3A headroom per channel to account for inrush transients during equipment startup. The expandable nature of the platform makes it suitable for phased deployments where camera counts or access points may increase over 3–5 years.

I've specified the MAXFIT77FE in several large retail and warehouse deployments where redundant power was a hard requirement. The dual-channel architecture is straightforward to work with: Channel A typically carries surveillance infrastructure, Channel B handles access control. This separation has proven invaluable during troubleshooting and allows you to isolate faults without powering down the entire site.
Technical Highlights:
- Dual Independent Channels: Two 24VDC @ 10A outputs eliminate shared power busses, reducing risk of cascading failures across disparate systems
- Expandable Platform: The MAXFIT77FE was designed from the ground up to integrate with additional Altronix modules, making it suitable for phased roll-outs and future capacity upgrades
Deployment Considerations:
- Verify total connected load does not exceed 10A per channel; typical IP camera deployments sit around 5–7A per channel with headroom built in
- The BC750 enclosure should be mounted in a climate-controlled space (equipment room, secure closet) to maximize component lifespan and avoid thermal stress
For integrators managing multi-site accounts or campuses with growth expectations, the MAXFIT77FE offers a clean path to scalability without re-architecting the power infrastructure. The dual-channel redundancy also simplifies maintenance windows—you can power down one channel for inspection while the secondary rail keeps critical access systems live.
System Design, Deployment & Technical Support
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price
System Design Assistance
- Get help validating product compatibility
- Coverage requirements
- Storage planning and deployment architecture before you buy.
Deployment & Configuration Support
- Access fixed-scope support for rollout planning
- User setup guidance
- Migration and system standardization across single-site or multi-site deployments
Guides, Tools & Calculators
- PoE requirements
- Storage retention
- Camera selection and deployment methodology