Overview

SKU: HLG-80H-48
Condition: New
Availability: Usually ships in 24 hours
Write a Review 35% OFF

Vivotek HLG-80H-48 48VDC 80W Industrial Power Supply

Vivotek HLG-80H-48 48VDC 80W Industrial Power Supply The Vivotek HLG-80H-48 is a professional-grade power supply engineered for demanding security an…

Add to cart for sale price
$108.00
$69.99
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Certified experts for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Bryan

Talk to Bryan

200+ hrs training • U.S - based

Certified Expert • 877-277-7147

Vivotek HLG-80H-48 48VDC 80W Industrial Power Supply

$108.00
$69.99

Your recommended setup

Review items below — quantities update pricing automatically.

Item Qty Status Price

Bundle Summary

Bundle Subtotal: $0.00
Optional Add-Ons: $0.00
Services: $0.00
Total: $0.00

Overview

SKU: HLG-80H-48
Condition: New
Availability: Usually ships in 24 hours
Description

Vivotek HLG-80H-48 48VDC 80W Industrial Power Supply

The Vivotek HLG-80H-48 is a professional-grade power supply engineered for demanding security and industrial applications. Delivering stable 48VDC output at 80W with an IP67 rating, this unit provides reliable power for IP cameras, network devices, and critical surveillance infrastructure in harsh environments ranging from -40°C to 70°C. Built for outdoor deployments and extreme conditions, it combines wide-range input compatibility with comprehensive protection mechanisms.

Key Features

  • IP67 Rated Protection: Fully sealed against dust ingress and water immersion up to 1 meter, ensuring reliability in outdoor and industrial environments
  • Wide Input Voltage Range: Accepts 90-305VAC input (47-63Hz), accommodating global electrical standards and fluctuating power conditions
  • Stable 48VDC Output: Delivers consistent 48V at 80W (81.6W rated) with ±1.0% voltage tolerance for sensitive equipment
  • Extended Temperature Operation: Functions reliably from -40°C to +70°C with temperature coefficient of ±0.03%/°C, ideal for extreme climates
  • High Efficiency Design: 91% typical efficiency with power factor >0.96 at full load, reducing energy waste and heat generation
  • Comprehensive Protection: Integrated overcurrent limiting, short-circuit hiccup mode, and overvoltage shutdown with automatic recovery
  • Low Ripple & Noise: Maximum 200mVp-p output ripple ensures clean power for sensitive surveillance and network equipment

Technical Specifications

  • Output: 48VDC, 1.7A rated current, 81.6W rated power
  • Input: 90-305VAC, 47-63Hz; 127-431VDC supported
  • Load/Line Regulation: ±0.5% each, with adjustable voltage range 43-53V
  • Isolation Resistance: 100M Ohms (I/P-O/P, I/P-FG, O/P-FG) at 500VDC
  • EMC Compliance: EN55015, EN61000-3-2/3-3, EN61347-1/2-13; EMI immunity to EN61000-4-2,3,4,5,6,8,11 with 4kV surge protection (light industry level)
  • Safety Standards: UL8750, CSA C22.2 No. 250.0-08, EN61347-1/2-13 compliance
  • Leakage Current: <0.75mA at 277VAC
  • MTBF: 357.8K hours minimum (MIL-HDBK-217F, 25°C)
  • Dimensions: 195.6 × 61.5 × 38.8mm; 0.84kg per unit

Applications

  • IP camera and surveillance system power in outdoor installations
  • Industrial network equipment and remote monitoring devices
  • Border security, transportation, and critical infrastructure deployments
  • Extreme climate environments requiring -40°C to 70°C operation
  • Installations requiring reliable power with minimal voltage regulation drift
Marty Allison
Marty Allison

The HLG-80H-48 is purpose-built for professional surveillance integrators requiring industrial-grade power reliability. Its 91% efficiency and high power factor (>0.96) minimize thermal stress in sealed enclosures, critical for -40°C outdoor operation where performance degradation is common. The ±0.5% line and load regulation specifications ensure camera equipment receives stable voltage despite AC supply fluctuations or cable voltage drops—particularly valuable in long-distance rural deployments.

IP67 certification combined with -40°C cold-start capability makes this unit exceptional for remote perimeter security where environmental sealing and extreme temperature operation are non-negotiable. EMC immunity to 4kV surge (light industry level) and hiccup-mode short-circuit protection provide adequate safeguarding for multi-unit installations on shared circuits. The specified 16ms hold-up time at full load ensures surveillance systems maintain operation during brief power interruptions, supporting uninterrupted video recording and network communication during grid disturbances.

Specifications
DC Input Voltage: 48V
CONSTANT CURRENT REGION: 28.8 ~ 48V
RATED CURRENT: 1.7A
RATED POWER: 81.6W
RIPPLE & NOISE (max: 200mVp-p
VOLTAGE ADJ. RANGE: 43 ~ 53V
CURRENT ADJ. RANGE: 1.02 ~ 1.7A Can be adjusted by internal potentiometer A type only
VOLTAGE TOLERANCE: ±1.0%
LINE REGULATION: ±0.5%
LOAD REGULATION: ±0.5%
SETUP, RISE TIME: 1200ms,80ms/115VAC 500ms,80ms/230VAC at full load; B type 1200ms,200ms/115VAC 500ms,200ms/230VAC at 95% load
HOLD UP TIME (Typ: 16ms at full load 230VAC /115VAC
VOLTAGE RANGE: 90 ~ 305VAC, 127 ~ 431VDC
FREQUENCY RANGE: 47 ~ 63Hz
POWER FACTOR (Typ: PF>0.96/115VAC, PF>0.96/230VAC, PF>0.94/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
TOTAL HARMONIC DISTORTION: THD< 20% when output loading≧60% at 115VAC/230VAC input and output loading≧75% at 277VAC input
EFFICIENCY (Typ: 0.91
AC CURRENT (Typ: 0.425A / 230VAC
INRUSH CURRENT (Typ: COLD START 70A(twidth=485μs measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A CIRCUIT BREAKER: 3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT:
OVER CURRENT: 95 ~ 108% Protection type: Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT: Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE: 54 ~ 63V Protection type: Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE: Shut down o/p voltage, re-power on to recover
WORKING TEMP: -40 ~ +70℃ (Refer to "Derating Curve")
WORKING HUMIDITY: 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY: -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT: ±0.03%/℃ (0 ~ 60℃)
VIBRATION: 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY STANDARDS: UL8750, CSA C22.2 No. 250.0-08(except for HLG-80H-48/54V & HLG-80H-48/54BL), UL8750 listed for HLG-80H-□BL, EN61347-1, EN61347-2-13 independent, optional models for J61347-1, J61347-2-13, IP65 or IP67 approved; Design refer to UL60950-1, TUV EN60950-
WITHSTAND VOLTAGE: I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
ISOLATION RESISTANCE: I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION: Compliance to EN55015, EN61000-3-2 Class C (≧60% load) ; EN61000-3-3
EMC IMMUNITY: Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A
MTBF: 357.8K hrs min. MIL-HDBK-217F (25℃)
DIMENSION: 195.6*61.5*38.8mm (L*W*H)
PACKING: 0.84Kg; 16pcs/14.4Kg/0.54CUFT
Product Type: Power Supply
Power Type: PoE
IP Rating: IP67
Q&A
Reviews
Have Questions? Ask an Expert.

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources