Overview

SKU: HLG-240H-54
Condition: New
Availability: Usually ships in 24 hours
Write a Review 33% OFF

Vivotek HLG-240H-54 Industrial Power Supply 240W

Vivotek HLG-240H-54 Industrial Power Supply 240WThe Vivotek HLG-240H-54 is a professional-grade DC power supply engineered for demanding surveillance …

Add to cart for sale price
$172.80
$114.99
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Certified experts for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Bryan

Talk to Bryan

200+ hrs training • U.S - based

Certified Expert • 877-277-7147

Vivotek HLG-240H-54 Industrial Power Supply 240W

$172.80
$114.99

Your recommended setup

Review items below — quantities update pricing automatically.

Item Qty Status Price

Bundle Summary

Bundle Subtotal: $0.00
Optional Add-Ons: $0.00
Services: $0.00
Total: $0.00

Overview

SKU: HLG-240H-54
Condition: New
Availability: Usually ships in 24 hours
Description

Vivotek HLG-240H-54 Industrial Power Supply 240W

The Vivotek HLG-240H-54 is a professional-grade DC power supply engineered for demanding surveillance and industrial applications. Delivering stable 54VDC at 240 watts with an extensive input range of 90–305VAC, this power supply maintains consistent performance across diverse electrical environments and global installations. Its IP67 rating and wide operating temperature range (-40°C to 70°C) make it ideal for outdoor, harsh, and extreme-climate deployments where reliability is non-negotiable.

Key Features

  • High Power Output: 54VDC at 240.3W rated capacity supports multiple high-demand devices
  • Wide Input Voltage Range: 90–305VAC input accommodates global electrical standards and variable power conditions
  • IP67 Rating: Complete protection against dust and temporary water immersion for outdoor installations
  • Extreme Temperature Operation: Reliable performance from -40°C to +70°C with automatic thermal protection
  • Comprehensive Protection: Overcurrent limiting, short-circuit hiccup mode, overvoltage shutdown, and over-temperature safeguards
  • High Efficiency: 93.5% typical efficiency reduces power consumption and heat generation
  • Fast Response: 80ms rise time and 15ms hold-up time ensure system stability during power transitions

Technical Specifications

  • Output Voltage: 54VDC with ±1.0% tolerance and 50–57V adjustment range
  • Rated Current: 4.45A (adjustable 2.23–4.45A via internal potentiometer)
  • Ripple & Noise: 350mVp-p maximum for clean, stable output
  • Input Frequency: 47–63Hz (universal AC compatibility)
  • Power Factor: >0.95 at 230VAC, >0.98 at 115VAC (full load)
  • Total Harmonic Distortion: <20% at ≥50% load (115VAC/230VAC)
  • Line & Load Regulation: ±0.5% each for precise voltage stability
  • Isolation Resistance: 100MΩ across all terminals (500VDC)
  • Withstand Voltage: 3.75KVAC input-to-output isolation
  • MTBF: 207.9K hours minimum (MIL-HDBK-217F at 25°C)

Safety & Compliance

The HLG-240H-54 meets international standards including UL1012, UL8750, UL60950-1, TÜV EN61347-1, EN61347-2-13, and CSA C22.2 certifications. EMC compliance covers EN55015, EN55022 (Class B), EN61000-3-2/3, and EN61000-4 immunity standards for light industrial environments. Leakage current remains below 0.75mA at 277VAC, ensuring user safety.

Applications

  • High-powered IP surveillance camera systems
  • Outdoor security installations in extreme climates
  • Industrial and critical infrastructure monitoring
  • Multi-camera deployments requiring centralized power distribution
  • Harsh environment installations (marine, mining, agricultural)
Eden Phillips
Eden Phillips

The HLG-240H-54 stands out for its robust feature set tailored to professional surveillance integrators. The 93.5% efficiency rating minimizes thermal stress in compact installations, while the comprehensive protection suite—constant-current limiting, hiccup-mode short-circuit recovery, and thermal shutdown—protects both the supply and connected devices. Wide voltage adjustment (50–57V) accommodates legacy and newer camera standards, and the high power factor (>0.95) reduces circuit breaker demands, allowing up to 4 units on a 16A Type C breaker at 230VAC.

The 15ms hold-up time and 80ms rise time ensure camera PoE systems maintain uptime during AC fluctuations. For outdoor deployments, IP67 rating combined with -40°C to 70°C operation covers virtually all climate conditions, while 207.9K MTBF indicates extended service life in continuous-duty applications. This supply is optimal for integrators building resilient, multi-camera systems in challenging environments where power consistency directly impacts system availability.

Specifications
DC Input Voltage: 54V
CONSTANT CURRENT REGION: 27 ~ 54V
RATED CURRENT: 4.45A
RATED POWER: 240.3W
RIPPLE & NOISE (max: 350mVp-p
VOLTAGE ADJ. RANGE: 50 ~ 57V
CURRENT ADJ. RANGE: 2.23 ~ 4.45A Can be adjusted by internal potentiometerA type and C type only
VOLTAGE TOLERANCE: ±1.0%
LINE REGULATION: ±0.5%
LOAD REGULATION: ±0.5%
SETUP, RISE TIME: 1000ms,80ms/115VAC 500ms,80ms/230VAC at full load
HOLD UP TIME (Typ: 15ms at full load 230VAC /115VAC
VOLTAGE RANGE: 90 ~ 305VAC, 127 ~ 431VDC
FREQUENCY RANGE: 47 ~ 63Hz
POWER FACTOR (Typ: PF>0.98/115VAC, PF>0.95/230VAC at full load (Please refer to "Power Factor Characteristic" curve)
TOTAL HARMONIC DISTORTION: THD< 20% when output loading≧50% at 115VAC/230VAC input and output loading≧75% at 277VAC input
EFFICIENCY (Typ: 0.935
AC CURRENT (Typ: 4A / 115VAC 2A / 230VAC 1.2A / 277VAC
INRUSH CURRENT (Typ: COLD START 75A(twidth=570μs measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A CIRCUIT BREAKER: 2 units (circuit breaker of type B) / 4 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT:
OVER CURRENT: 95 ~ 108% Protection type : Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT: Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE: 60 ~ 67V Protection type : Shut down and latch off o/p voltage, re-power on to recover
OVER TEMPERATURE: Shut down o/p voltage, recovers automatically after temperature goes down
WORKING TEMP: -40 ~ +70℃ (Refer to "Derating Curve")
WORKING HUMIDITY: 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY: -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT: ±0.03%/℃ (0 ~ 50℃)
VIBRATION: 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY STANDARDS: UL1012, CAN/CSA-C22.2 No. 107.1-01, UL8750, CSA C22.2 No. 250.0-08, TUV EN61347-1, EN61347-2-13 independent (except for HLG-240H C type), UL60950-1, UL8750, TUV EN60950-1, IP65 or IP67, J61347-1, J61347-2-13 approved
WITHSTAND VOLTAGE: I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
ISOLATION RESISTANCE: I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION: Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C (≧50% load) ; EN61000-3-3
EMC IMMUNITY: Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria B
MTBF: 207.9K hrs min. MIL-HDBK-217F (25℃)
DIMENSION: 251*68*38.8mm (L*W*H)(HLG-240H-C)
PACKING: 1.23Kg; 12pcs/15.8Kg/1.16CUFT(HLG-240-C)
Product Type: Power Supply
Power Type: DC
IP Rating: IP67
Q&A
Reviews
Have Questions? Ask an Expert.

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources